11
Converting to cartridges
The Dragonfly X2 is fully compatible with cartridges and is easier to convert than the
previous model. When using cartridges the Stay up spring
must be removed to prevent
strain on the motor
and to function properly. The X2 version has a lid in the frame that allows
quick access to the Stay up spring. To properly convert we recommend the Precision tool kit
.
Remove the Stay up spring by removing the Lid on the side of the frame. After removing the
Stay up spring, put the lid and screw back in place. If you wish to use standard needles again
put the stay up spring back. Use the short end of the 1.5mm Allen key to push and hold it in
place. Put the lid back in position and keep some pressure on the lid while pulling the Allen
key out. The stay up spring should engage so that it rests on the lid.
To take advantage of the give function when using cartridges the Inner piston spring should
be replaced. If the give function is not required just adjust the give to the bottom position
(hardest setting).
Stay up spring
Lid Screw
Spring Lid
Inner piston spring
Standard 2260
Cartridges 2281
1.3mm Hex key