Output(WORK1/WORK2) Instruction
WORK1:
The P1 heating/cooling output
WORK2:
The P2 heating/cooling output
Indicator LED:
●
Red LED is on WORK1 output is on.
●
Red LED is blinking WORK1 output is performing the
function of compressor delay.
●
Green LED is on WORK2 output is on.
●
Green LED is blinking WORK2 output is performing the
function of compressor delay.
●
Yellow LED is on The controller is in the setting mode.
Button Instruction
Please read the detail on
2.Button Operation Instructions
below
Probe interface
Two temperature probes can be insert into P1 and P2 interface.
Temperature probe
●
If the controller display Er, you may get a false temperature
probe, please try harder to insert the probe and rotate it to make
good contact. If the problem is still persists, it is likely the
internal probe wire has been damaged by the moisture or heat
temperature.
●
The probe and cable cannot be touched by the flame.
●
Do not exceed the probe temperature range to avoid
damaging.
2 Button Operation Instructions
2.1 Restore Default Settings
Press and hold the “ " button to power on, the buzzer will
make a short call, indicating that all parameters of the user's
temperature and humidity probe function return to the default
setting value.
2.2 “ ” and “ ”Button Function in Normal Operation
Mode
Press the “ ", PV shows the current temperature setting
value , SV shows current humidification value; press “ ", PV
shows current temperature value, SV the current humidification
setting value , and It will be back to the normal display if there is
no operation for 3 seconds orpressing the "
SET
" button.
2.3 “SET” Button Function in Normal Operation Mode
Short press the “
SET
” button to enter the quick setting
temperature and humidity value mode. PV shows the current
temperature setting value and flashes, and short press “ ” or
“ ” button to increase or decrease the setting value, long
press “ ” or “ ”button to quickly increase or decrease the
setting value, Short press the “
SET
” button again
,
SV shows
the current humidity setting value and flashes, and short press
“ ” or “ ” button to increase or decrease the setting value,
long press “ ” or “ ”button to quickly increase or decrease
the setting value and lastly press the "
SET
" button again to
confirm and exit. If there is no operation, it will automatically
exit after 10 seconds and save the setting value.
2.4 Button Function in Setting Mode
When the controller is working normally, press the “
SET
” button
for 2 seconds to enter the setting mode
,
the PV shows the first
menu code“
”, SV shows the corresponding setting value.
Press “
SET
” button to scroll down the menu item and save the
parameters of the previous menu item. Press“ ” or
“ ”button to change the current setting value. Selected T to
enter the temperature parameter modification mode; selected H
to enter the humidity parameter modification mode. If in the
setting state, there is no operation within 30 seconds or long
press "
SET
" button for 2 seconds, it will exit and save the
setting state and return to normal operation mode.
3.2 Setting Menu Instruction
Y
N
Heating or Cooling Mode
Humidi
fi
cationi or
Dehumidi
fi
cation Mode
Temperature Setting Value
Humidity Setting Value
Heating or Cooling
difference value
Humidi
fi
cationi or
Dehumidi
fi
cation
difference value
Alarm High
Temperature Limit
Alarm High Humidity Limit
SET
SET
Alarm Low
Temperature Limit
Alarm Low Humidity Limit
Compressor Delay Time
Compressor Delay Time
Temperature Calibration
Humidity Calibration
N
Y
Y
Press "SET" Key for over 2
seconds to enter parameters
setting mode
TS
77.0
℉
DS
AH
AL
PT
0Minute
CA
SET
SET
SET
SET
SET
SET
SET
HC
H
No Key for 30 seconds or Presss
"SET" key for over 2 second ?
Working normally
=T?
HS
50.0
%
RH
DS
5.0
%
RH
AH
99.0
%
RH
AL
5.0
%
RH
PT
0Minute
CA
0.0
%
RH
SET
SET
SET
SET
SET
SET
SET
HD
H
3 Menu Instruction
3.1 Setting mode Flow Chart
3 .2.1 When
is H
Code
Symbol
Function
Setting Range
Default
Setting
HD
Humidi
fi
cation or
Dehumidi
fi
cation Mode
H or D
H
HS
HS
Humidity Setting Value
5.0
%RH
~99
.0%RH
50
%RH
DS
s
Humidi
fi
cation or
Dehumidi
fi
cation Difference
Value
1.0
%RH
~20
.0%RH
5%RH
AH
AH
Alarm High Humidity Limit
5.0
%RH
~99
.0%RH
99
.0%RH
AL
AL
Alarm Low Humidity Limit
5.0
%RH
~99
.0%RH
5.0
%RH
PT
Compressor Delay Time
0
~
10 minutes
0 minute
CA
CA
Humidity Calibration
-20
.0%RH
~20
.0%RH
0%RH
H
P
Содержание ITC-608T
Страница 1: ...ITC 608T Manual...
Страница 6: ...4 TEMPERATURE Controller Manual Equivalent to ITC 308 Temperature Controller Manual ITC 608T Part 2...
Страница 7: ...5 86 8f 96 0f WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...
Страница 15: ...13 86 8f 96 0f WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...
Страница 28: ...26 DUAL TEMPERATURE PROBES Controller Manual ITC 608T Part 4...
Страница 29: ...27 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller 88 6f 98 6f...
Страница 38: ...36 HUMIDITY Controller Manual Equivalent to IHC 200 Humidity Controller Manual ITC 608T Part 5...
Страница 39: ...37 56 8 66 0 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...
Страница 46: ...44 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller 88 6f 56 8...
Страница 54: ...Inkbird Tech C L support ink bird com www ink bird com 86 755 25738050 Shenzhen GD 518000 China...