14

  

     Functions on screen

PV

In normal mode, the measured  temperature is 

displayed. In settings mode, it will display menu code.

SV

In normal mode, the  temperature  setting value is 

displayed. In setting mode, it will display the setting value.

       

Output(WORK1/WORK2) Instruction

WORK1: 

The heating output

WORK2: 

The cooling output

      

 Indicator LED

Red LED is on

        

WORK1 output is on.

Green LED is on

          

WORK2 output is on.

Green LED is blinking

         

WORK2 output is performing the 

function of compressor delay.

Yellow LED is on

          

The controller is in the setting mode.

     

    

Button Instruction

Please read the detail on 

2.Button Operation Instructions 

 

below.

          

Probe interface

Temperature probe can be insert into P1 or P2 interface.

     

    Temperature probe

     If the controller display Er, you may get a false temperature  
probe, please try harder to insert the probe and rotate it to 
make good contact. If the problem is still persists, it is likely 
the internal probe wire has been damaged by the moisture or 
heat temperature.
     The probe and cable cannot be touched by the flame.

     Do not exceed the probe temperature range to  avoid 

damaging.

.

A   

B   

D   

E   

F   

C  

Содержание ITC-608T

Страница 1: ...ITC 608T Manual...

Страница 2: ...d Into 6 Parts Part 2 Temperature Controller Manual Part 3 Programmable Temperature Controller Manual Part 5 Humidity Controller Manual Part 6 Humidity Temperature Controller Manual 1 4 12 36 Part 4 D...

Страница 3: ...ture Controller Manual PROGRAMMABLE TEMPERATURE Controller Manual Equivalent to ITC 310T B Temperature Controller Manual ITC 608T ITC 608T Temperature Control Mode ITC 608T Temperature Probe 2 Quick G...

Страница 4: ...ahrenheit Fahrenheit Error 40 T 10 2 40 T 50 3 10 T 80 1 50 T 176 2 80 T 100 2 176 T 212 3 Humidity Probe optional Type of humidity probe HTG3515CH Relative humidity measurement range 5 99 RH Humidity...

Страница 5: ...year from the date of purchase when operated under normal condition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to...

Страница 6: ...4 TEMPERATURE Controller Manual Equivalent to ITC 308 Temperature Controller Manual ITC 608T Part 2...

Страница 7: ...5 86 8f 96 0f WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...

Страница 8: ...he function of compressor delay Yellow LED is on The controller is in the setting mode Button Instruction Please read the detail on 2 Button Operation Instructionsbelow Probe interface Temperature pro...

Страница 9: ...value and flashes and short press or button to increase or decrease the setting value long press or button to quickly increase or decrease the setting value nally press the SET button again to con rm...

Страница 10: ...rm High Temperature Limit Alarm Low Temperature Limit Compressor Delay Time Temperature Calibration Temperature Unit Press SET Key forover2 seconds to enterparameters setting mode TS 77 0 HD CD AH AL...

Страница 11: ...ature setting value and automatically recognizes and converts for the heating or cooling working mode in which WORK1 is the heating output furthermore the red led is the WORK1 heating output status in...

Страница 12: ...ate When PV measured temperature value 25 0 C the cooling stops Then return to normal temperature control When PV measured temperature value 25 0 C it enter the heating state when PV measured temperat...

Страница 13: ...on CA When the measured temperature deviates from the standard temperature the temperature calibration function can be used to make the measured value of the instrument consistent with the standard va...

Страница 14: ...12 PROGRAMMABLE TEMPERATURE Controller Manual Equivalent to ITC 310T B Temperature Controller Manual ITC 608T Part 3...

Страница 15: ...13 86 8f 96 0f WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...

Страница 16: ...he function of compressor delay Yellow LED is on The controller is in the setting mode Button Instruction Please read the detail on 2 Button Operation Instructions below Probe interface Temperature pr...

Страница 17: ...TR 1 or 2 Press PV shows current time unit SV shows the current remaining working time And It will be back to the normal display if there is no operation for 3 seconds or pressing the SET button Press...

Страница 18: ...press or to modify the setting value Press SET button again to con rm and exit If there is no operation for 3 seconds It will automatically exit after 10 seconds and save the setting value 2 5 Button...

Страница 19: ...Qty of stages depend on the STT Value Compressor Delay Time Stage12 Temperature Set Value Temperature Calibration Stage12 Duration Length Temperature Unit Stage12 User De ned Alert at the end of stag...

Страница 20: ...ture Setting Value 25 0 or 77 0 H03 H03 Stage 3 Control Duration Value 10 U03 U03 Whether to Alarm after the Completion of Stage 3 n S04 S04 Stage 4 Temperature Setting Value 25 0 or 77 0 H04 H04 Stag...

Страница 21: ...eating or cooling working mode in which WORK1 is the heating output furthermore the red led is the WORK1 heating output status indicator WORK2 is cooling output furthermore the green led is WORK2 cool...

Страница 22: ...to normal temperature control When PV measured temperature value 25 0 C it enter the heating state when PV measured temperature value 25 0 C heating stops and then return to normal temperature contro...

Страница 23: ...to make the measured value of the instrument consistent with the standard value The calibrated temperature the measured temperature the calibration value 4 5 Fahrenheit or Celsius Settings CF The use...

Страница 24: ...he temperature of the time period Regarding the difference between TR 1 Continuous Timer Mode and TR 2 Target Timer Mode the following table illustrates their differences in details Stage X N 1 12 STX...

Страница 25: ...the stage control time H01 H03 is only started when the current temperature reaches the setting temperature of the current stage such as 5 14 19 25 32 35 and total is 39 minutes 4 6 3 UT is a time un...

Страница 26: ...ately Press any button at this time to cancel the buzzer alarm and return to normal display If the cycle index MD is completed PV will show the current temperature and SV will show End 4 6 8 3 UX C If...

Страница 27: ...AT 1 Automatic Mode after the power is turned off the time still counts After the power is turned on again when TR 1 and UX X 01 12 is n or A the temperature controller will automatically calculate t...

Страница 28: ...26 DUAL TEMPERATURE PROBES Controller Manual ITC 608T Part 4...

Страница 29: ...27 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller 88 6f 98 6f...

Страница 30: ...mode the indicator LED is on otherwise off SV In normal mode the P2 measured temperature is displayed In setting mode it will display the setting value P2 Heating indicator LED If P2 Temperature Cont...

Страница 31: ...s in the setting mode Button Instruction Please read the detail on 2 Button Operation Instructionsbelow Probe interface Two temperature probes can be insert into P1 and P2 interface Temperature probe...

Страница 32: ...rease or decrease the setting value and then press SET again SV shows the temperature setting value of probe 2 and flashes at this time quickly press or button to increase or decrease the setting valu...

Страница 33: ...77 0 DS1 3 0 AH1 212 AH1 212 Heating or Cooling difference value STE Alarm High Temperature Limit STE Alarm Low Temperature Limit STE PT1 0Minute Working normally Compressor Delay Time STE CA1 0 0 Te...

Страница 34: ...9 9 9 9 15 0 15 0 100 212 40 0 40 0 0 minute 0 0 0 0 25 0 77 0 2 0 100 212 40 0 40 0 40 0 100 40 0 212 0 3 15 0 40 0 100 40 0 212 40 0 100 40 0 212 0 10minute 9 9 9 9 15 0 15 0 25 0 77 0 2 0 F H 3 0...

Страница 35: ...of Probe 2 When HC2 H the temperature mode is heating mode SV LED1 is on and when the measured temperature temperature setting value TS2 difference value DS2 it enters the heating state the WORK2 ind...

Страница 36: ...ternate AL2 with current temperature buzzer will bi bi Biii alarm until the tempera ture AL2 buzzer off and return to normal display and control Or press any button to turn the buzzer alarm off only 5...

Страница 37: ...heit or Celsius according to their habits The default temperature is Fahrenheit If you need to display the unit in Celsius then set the CF to C Please note that when the CF changes state all setting v...

Страница 38: ...36 HUMIDITY Controller Manual Equivalent to IHC 200 Humidity Controller Manual ITC 608T Part 5...

Страница 39: ...37 56 8 66 0 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller...

Страница 40: ...ng the function of compressor delay Yellow LED is on The controller is in the setting mode Button Instruction Please read the detail on 2 Button Operation Instructions below Probe interface Humidity p...

Страница 41: ...ty value and flashes and short press or button to increase or decrease the setting value long press or button to quickly increase or decrease the setting value and press the SET button again to con rm...

Страница 42: ...larm High humidity Limit SET Alarm Low humidity Limit Compressor Delay Time Humidity Calibration Press SET Key forover2 seconds to enterparameters setting mode HD 5 0 RH DD 5 0 RH AH 99 0 RH AL 5 0 RH...

Страница 43: ...humidi ca tion output status indicator WORK2 is dehumidi cation output furthermore the green led is WORK2 dehumidi cation output status indicator When PV measured humidity HS humidity setting value HD...

Страница 44: ...3 Dehumidifying Delay Protection Time PT In the dehumidifying mode when the power is turned on for the rst time it will not start dehumidi cation immediately when PV measured humidity value HS humidit...

Страница 45: ...TEMPERATURE HUMIDITY Controller Manual Equivalent to IHC 230 Temperature Humidity Controller Manual ITC 608T 43 Part 6...

Страница 46: ...44 WORK1 WORK2 A B C D E F P1 P2 1 Get to Know the Controller 88 6f 56 8...

Страница 47: ...e indicator LED is on otherwise off SV In normal mode the measured humidity is displayed In setting mode it will display the setting value Humidi cation indicator LED If humidity Control Function sele...

Страница 48: ...nstruction Please read the detail on 2 Button Operation Instructions below Probe interface Temperature or humidity probe can be insert into P1 or P2 Temperature humidity probe If the controller displa...

Страница 49: ...ckly increase or decrease the setting value Short press the SET button again SV shows the current humidity setting value and flashes and short press or button to increase or decrease the setting value...

Страница 50: ...AH AL PT 0Minute CA SET SET SET SET SET SET SET HC H No Key for 30 seconds or Presss SET key for over2 second Working normally T HS 50 0 RH DS 5 0 RH AH 99 0 RH AL 5 0 RH PT 0Minute CA 0 0 RH SET SET...

Страница 51: ...dicator LED to indicate whether the user has chosen humidi cation or dehumidi cation The WORK1 is output control of Temperature furthermore the red led is the WORK1 output status indicator the WORK2 i...

Страница 52: ...off and return to normal display and control Or press the button to turn the buzzer alarm off only When measured temperature AL low temperature limit alarm PV shows alternate AL with current temperatu...

Страница 53: ...are less than the delay time it needs to operate the remaining delay time to start dehumidi cation Delay time will start counting from the WORK2 output off 4 6 Temperature and Humidity Calibration CA...

Страница 54: ...Inkbird Tech C L support ink bird com www ink bird com 86 755 25738050 Shenzhen GD 518000 China...

Отзывы: