FAULT SIGNALS
The following table shows how system faults, indicated by the yellow LED,
are signaled clearly on the keypad
:
For the “
Low battery WLS
” and “
WLS zone loss
”, access “View/
Faults”, on the User menu, then press
to access the list of devices
involved in the fault event.
FAULT
User menu string: “View/
Faults”
Probable cause
Solution
Zone fuse blown
Zone fuse fault
Excessive current draw on the
“+AUX” terminals on the control
panel
Call your Installer company
BUS fuse blown
I-BUS fuse fault
Excessive current draw on the “+”
terminal on the control panel
Call your Installer company
Backup battery low or
disconnected
Low battery
The control panel backup-battery is
running low or is not connected
properly
Call your Installer company
Mains failure
Mains failure
The primary power source (230
Vac) has failed (blackout) or is not
connected properly
Check all connections and the
mains electrical-circuitry
Telephone line down
Tel. line down
The telephone line is not working
Check the telephone cabling or
contact your provider company for
service
Wireless noise
Jamming
Rogue wireless signal
Check that there are no sources of
rogue wireless signals in the
vicinity
Low wireless-detector battery
Low battery WLS
The battery of at least one wireless
detector is running out
Replace the battery of the detector
concerned
Wireless detector loss
WLS zone loss
At least one wireless detector is not
responding (lost)
Call your Installer company