12
Device description
Telephone dialler
In the event of the presence of more than one fault, LED 2 will
indicate all the faults one at a time.
ATTENTION!
Some operations (for example, calls to alarm receiving centres
using Contact-ID, SIA-IP, 10 and 20bps protocols) require that at
least two light-blue LEDs are ON solid.
The SmartLinkAdv provides further LED signalling, in addition to the
above-mentioned cases, indicated by the simultaneous lighting of
several LEDs:
•
During the programming and initializing phases all six LEDs must
flash simultaneously.
•
SmartLinkAdv is predisposed for the “Easyscan” function and
“Easyscan” active function (refer to paragraph 3-7 Easyscan):
successive activation in cyclic mode of all the LEDs starting from
LED 6 to LED 1.
•
Incoming SMS:
successive activation in non-cyclic mode of one LED at a time
starting from LED 1 to LED 6.
BUZZER
The buzzer provides the end-user with audible signalling.
The buzzer provides entry time, exit time and command
confirmation signals (if programmed). Activation of these signals
can be configured during the programming phase.
Table 2-5:
LED signalling
LED
Status
Num.
Colour
Signalling
ON
OFF
Slow flashing
Fast flashing
1
Green
Operating
status
Device
operating
Device initializing
2
Red
Fault
No faults
present
Flash cycle followed by pause:
• 1 flash: general battery fault
• 2 flashes: telephone line fault
• 3 flashes: GSM network trouble
• 4 flashes: low credit warning
3
Yellow
SmartLinkAdv
operating status
Communication
status
SmartLinkAdv
armed
SmartLinkAdv
disarmed and
there are no
ongoing calls
SmartLinkAdv
disarmed and one
call is ongoing
SmartLinkAdv
armed and there is
one ongoing call
4
Light blue
GSM reception
status
GSM signal quality:
• One LED On: poor signal
reception
• Two LEDs On: average signal
reception
• Three LEDs On: optimum
signal reception
One LED flashing: average signal reception
between two of the three predefined levels.
All three LEDs flashing: no GSM reception
5
Light blue
6
Light blue
Table 2-6:
Signalling and signal type
Signalling
Signal type
Entry time running
Short pulse cycles
Entry time running
Long pulse cycles
Command carried out
3 short pulses
Command not carried out
5 long pulses