Страница 1: ...1 Installation and programming manual SmartLink Advanced Telephone dialler Installation and programming manual EN 50131 1 EN 50131 10 EN 50136 1 EN 50136 2 EN 50130 4 EN 50130 5 CEB T014 ...

Страница 2: ... to defects in parts and workmanship relating to normal use It does not cover damage arising from improper maintenance or negligence damage caused by fire flood wind or lightning vandalism fair wear and tear INIM Electronics s r l shall at its option repair or replace any defective products Improper use that is use for purposes other than those mentioned in this manual will void the warranty Conta...

Страница 3: ...documentation 8 Chapter 2 Device description 9 2 1 Unpacking the device 9 2 2 Accessory items 9 2 3 Technical description 9 2 4 Signalling from device 11 Chapter 3 SmartLinkAdv functions 13 3 1 Telephone line down management 13 3 2 Input Output terminals 13 3 3 Event activations 14 3 4 Dialler function 14 3 5 Command and Shortcuts 15 3 6 Remote activation 15 3 7 Easyscan 17 3 8 Jamming detector 17...

Страница 4: ... Chapter 6 Project development and programming 28 6 1 Using the SmartLeague software program 28 6 2 Using the software program 29 6 3 Programming via the software 30 6 4 Reset default settings 31 6 5 Maintenance and monitoring 31 Chapter 7 EN50136 Compliance 33 7 1 ATS Categories 33 7 2 Access Levels 34 7 3 Connection with alarm control panel Control and Indicating Equipment 34 Appendix A Events 3...

Страница 5: ...n directly in front of the mounted device SELECT Click on a specific item on the interface drop down menu options box graphic object etc PRESS Click on a video button or push a key on the control panel keypad 0 2 Graphic conventions Following are the graphic conventions used in this manual Note The Note sections contain important information relating to the text ATTENTION The Attention prompts ind...

Страница 6: ... the SmartLinkAdv operates as a simulated line it tests the PSTN line periodically to check if the communication problems have cleared If the PSTN line is found to be operating normally and there are no ongoing telephone calls passing through the interface the system will switch back to the main PSTN line Otherwise it will switch back to the PSTN only when all the necessary outgoing calls have bee...

Страница 7: ...ion function Dialler over GSM network and PSTN landline and GPRS modem Dialler over PSTN landline SMS dialler over GSM network Manages DTMF commands over GSM network Manages DTMF commands over PSTN landline Priority channel choice between SM network and PSTN landline Fault signalling Incoming SMS divert Actions using Caller ID Manages commands via SMS with code or identifier of the sender Ring or ...

Страница 8: ... manual SmartLeague software programming manual The manuals are regularly supplied with the apparatus and can be downloaded from the Download section of our website www inim biz The installation manual is included in the package To order further copies contact the offices at INIM Electronics ...

Страница 9: ...kit does not include 1 2 A h battery Switching power supply battery charger SIM card Note These items must be purchased before beginning the installation phase 2 2 Accessory items The following accessory devices are individually packed and must be ordered separately IPS12015 Switching power supply battery charger TamperNO dislodgement tamper protection Remote antenna for indoor use High performanc...

Страница 10: ...ement hole G Default data reset button H Buzzer I Activity LED J GSM signal reception LED A B C E F H D PCB board Metal backbox A G J I K L L L L M M M M N N P O Table 2 2 Terminals on the terminal board n icon identifier function 1 14V Positive power terminal 2 14V Negative power terminal 3 AUX 12V Ancillary power supply 4 Power supply negative earth or GND 5 6 7 8 9 T1 T2 T3 T4 T5 Control panel ...

Страница 11: ...CB current draw during standby status 40 mA 100 mA during transmission 300 mA maximum 70 mA 600 mA Maximum current draw of AUX terminals 400 mA Switching power supply 14V 1 05A Backup battery 12V 1 2Ah lead battery with UL94HB flame class or higher Inputs 5 Outputs total 5 Type 150 mA open collector output GSM frequency band 850 900 1800 and 1900 Mhz Quad band Number of events recorded 1000 Operat...

Страница 12: ...ignals if programmed Activation of these signals can be configured during the programming phase Table 2 5 LED signalling LED Status Num Colour Signalling ON OFF Slow flashing Fast flashing 1 Green Operating status Device operating Device initializing 2 Red Fault No faults present Flash cycle followed by pause 1 flash general battery fault 2 flashes telephone line fault 3 flashes GSM network troubl...

Страница 13: ...as been down for the programmed time 3 2 Input Output terminals The five terminals 5 9 can be configured individually as Input zone terminal Double zone terminal ZONE DOUBLING Output terminal Controlled output terminal I O Unused terminal INPUT ZONE An electrical input point used for the management supervision of signals coming from a device The activation of the signal may cause the SmartLinkAdv ...

Страница 14: ...igital protocol messages send SMS messages In Appendix A Events you can find the complete list of events generated by the SmartLinkAdv 3 4 Dialler function DIGITAL The digital dialler function generates digital protocol calls directly to alarm receiving centres The available protocols are Ademco 10bps Ademco 14bps Franklin 20bps Radionics 40bps Scantronic 10bps Contact ID SIA IP SMS FUNCTION The S...

Страница 15: ...ive to the GSM network commands and user codes Table 3 1 Available shortcuts description function parameter note Arm Disarm Applies a preset scenario which scenario Shortcuts are available only when the SmartLinkAdv is programmed as an intrusion control panel Stop alarms Deactivates instantly the outputs activated by alarm and tamper events Delete memory Carries out a Stop alarms operation and at ...

Страница 16: ... an SMS text indicating the remaining credit STATUS for enquiries relating to the status of the SmartLinkAdv the user will receive an SMS text indicating device name and firmware revision GSM network provider GSM signal reception level Presence of the PSTN line list of faults present device tamper status power supply of the circuit armed disarmed status of the SmartLinkAdv list of zones in alarm s...

Страница 17: ...a programmed number of rings the SmartLinkAdv will engage the line and play the voice message Type in code followed by 3 Enter a valid user code then press on the telephone key pad 4 The SmartLinkAdv will start a voice message listing the short cuts associated with the entered code and the corresponding keys on the telephone keypad voice menu 5 Activate the required commands by pressing the corres...

Страница 18: ...t optional 5 1 Fit the anti dislodgement bracket into its housing on the back of the control panel table 2 1 O 5 2 Using screw location screw the bracket to the wall where the box is mounted 5 3 Cut off the connector of the anti dislodgement device and strip the two wires 5 4 Connect one of the wire to a T terminal table 2 2 5 6 7 8 9 configured as a normally closed and the other to the ground ter...

Страница 19: ...g 2 Remove the nut and washer that are screwed onto the antenna 3 Pass the antenna cable through the cable entry on the top of the enclosure into its housing table 2 1 P 4 Using the nut and washer secure the antenna in place 5 Connect the antenna wire to the respective connector on the PCB table 2 1 F REMOTE ANTENNA If it necessary to mount the SmartLinkAdv in a part of a building where the GSM re...

Страница 20: ... must be connected to earth and connected equipotentially to terminal 2 Table 2 2 Terminals on the terminal board ATTENTION This operation is necessary in order to comply with the security requirements of the telecommunications network and also to protect the device against overload and or electrical discharge coming from the external telephone line 4 6 Inserting the SIM card Deactivate the PIN co...

Страница 21: ...ommand Once the GPRS parameter settings are complete you will be able to activate the GPRS connection by means of the following procedure 1 Start the SmartLeague software program and access the Set tings Application settings menu section Select Connection via GPRS from the options available in the Communication type section then press Start 2 The Start button opens the GPRS connection status secti...

Страница 22: ... mode is as secure as Double balanced mode if the tamper contact of the detector is connected to a balanced zone on the SmartLinkAdv 4 8 1 N C N O Balancing For N C normally closed and N O balancing normally open it is possible to detect two distinct zone conditions standby alarm For each of these the SmartLinkAdv reads different values of the equivalent resistance on the terminal shown below in O...

Страница 23: ... below in Ohm 4 8 3 Double balancing Double balancing discriminates 4 distinct conditions on the zone terminal standby alarm tamper short circuit tamper wire cutting For each of these the SmartLinkAdv reads different values of the equivalent resistance on the terminal shown below in Ohm Ohm Zone 6800 alarm 6800 standby 0 tamper A l a r m 12V GND Tamper 6K8Ohm 1 4W Ohm Zone 6800 tamper wire cutting...

Страница 24: ...h zones alarm on zone 1 and standby on zone 2 alarm on zone 2 and standby on zone 1 alarm on both zones tamper wire cutting tamper short circuit For each of these the SmartLinkAdv reads different values of the equivalent resistance on the terminal shown below in Ohm Ohm Zone 1 Zone 2 double 3900 6800 tamper 3900 6800 alarm alarm 6800 standby alarm 3900 alarm standby 0 standby standby A l a r m 12V...

Страница 25: ...esponse to a recognized event All the outputs are open collector outputs capable of sinking a maximum current of 150mA The wiring diagram below illustrates a series of typical connections for the activation of a load when a Normally Open output closes to GND SmartLinkAdv PCB Generic load 12V External power supply 13 8V Generic device ...

Страница 26: ...system 10 Insert the SIM card 11 Restore power to the system 5 1 Initializing phase On powerup the device carries out a self diagnosis phase During this phase all the LEDs will flash If no anomalies are detected during the self diagnosis phase the device will initialize the normal operating phase after approximately 30 seconds Initialization of the normal operating phase is signalled by the deacti...

Страница 27: ...v will reinitialize and restart the Easyscan phase This procedure is cyclical 3 Connecting the SmartLinkAdv to a PC paragraph 4 7 PC Con nection 4 Start the SmartLeague software program and open SmartLink Advanced solution 5 Go to the Monitoring Easyscan 6 Click on the Connect SmartLink button to start the connec tion with the GSM module Once the connection is made the normal software functions Pr...

Страница 28: ... and allows the preparation of the larger part of the SmartLinkAdv parameters without actually being connected to the device The connection is required when uploading data writing on the SmartLinkAdv or downloading data reading from the SmartLinkAdv The type of connection depends on the means used refer to paragraph 4 7 PC Connection The programming parameters of an installation constitute the sol...

Страница 29: ...le to compare different solutions and even keep two solutions open one real and one for test purposes in order to verify the effects of programming When a solution opens the SmartLeague software program presents the following interface Table 6 1 SmartLeague software program homepage A Open solutions bar B List of recent solutions which will allow you create new solutions or open existing solutions...

Страница 30: ...of the ongoing project programming data for download operations for upload operations These buttons will upload download all the system data including any ongoing programming Whereas if you are working on a message programming section these buttons will upload download only the data on the open template 6 3 Programming via the software The SmartLinkAdv can be programmed exclusively through the Sma...

Страница 31: ...n order to reset default programming on the SmartLinkAdv simply work through the following steps 1 Remove all power from the SmartLinkAdv 2 Press and hold the reset button refer to table 2 1 G 3 Hold down the reset button and restore power to the Smar tLinkAdv 4 Wait 5 seconds 5 Release the button The SmartLinkAdv will restart with the factory default settings 6 5 Maintenance and monitoring The ma...

Страница 32: ...f the system Easyscan for easy scanning of GSM network signal reception Refer to the SmartLeague software program manual for the descriptions of the sections and the parameters being viewed The manufacturer strongly advises that the following procedures are carried regularly Clean the SmartLinkAdv Check there are no inappropriate objects inside the box Check the functionality of the LEDs Check the...

Страница 33: ...e used to create an ATS Alarm Transmission System in accordance with the definitions in standards EN 50136 1 and EN 50136 2 Note If the SmartLinkAdv is used as an SPT Supervised Premises Transceiver for an ATS Alarm Transmission System it must be powered by the AS Alarm System and not by an IPS12015 power supply which is not allowed Table 7 1 Maximum ATS categories ATS achievable SPT Model SPT pri...

Страница 34: ... SmartLinkAdvanced System from the tree structure then go to the Installer Code section underProgramming 7 Allow the installer to enter the installer code then press Enroll 8 Allow the user to enter the user code then press OK At this point the installer has registered installer access and can work on the device programming parameters 7 3 Connection with alarm control panel Control and Indicating ...

Страница 35: ... C N O Balancing This terminal must be configured as an output associated with the SmartLinkAdv open panel tamper event In this way dislodgement or open tamper on the SmartLinkAdv will generate an SPT Tamper event in the control panel T4 Terminal T4 must be connected to a CIE input with normally open balance refer to paragraph 4 8 1 N C N O Balancing This terminal must be configured as normally op...

Страница 36: ...zone type and the armed disarmed status Not ready to arm A zone is not in standby status All the zones are in standby status 1 no Away arming request A request is made to arm in Away mode A request is made to disarm the partition 1 Yes Stay arming request A request is made to arm in Stay or in Instant mode A request is made to disarm the partition 1 Yes Arming effective SmartLinkAdv is effectively...

Страница 37: ... no SMS message not delivered Failure to send an SMS message through the GSM module has occurred 1 Yes Output fault An output fails to switch status as commanded 1 Yes Low credit The credit left on the SIM card is below the minimum credit threshold The remaining credit is above the minimum credit threshold 1 no Unsuccessful call over PSTN The call sent via PSTN has not been received 1 Yes Unsucces...

Страница 38: ...s s r l dichiara che questo SmartLinkAdv è con forme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Lietuviž Šiuo INIM Electronics s r l deklaruoja kad šis SmartLinkAdv atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas English Hereby INIM Electronics s r l declares that this SmartLinkAdv is in compliance with the essential req...

Страница 39: ...39 Installation and programming manual Notes ...

Страница 40: ...ialler Centobuchi via Dei Lavoratori 10 63076 Monteprandone AP ITALY Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 ...