Installation and User Guide 

 

 

KETS 1141 

Titan Illuminated 

Crossing Telephone 

 

WARNING 

THIS TELEPHONE REQUIRES A SPECIFIC SET UP PROCEDURE, 

DETAILED IN THIS MANUAL. 

 

PHONES MAY FAIL TO OPERATE IF NOT SET UP 

CORRECTLY ON INSTALLATION. 

 

GAI-TRONICS 

1

2

3

Press

LIFT

HANDSE T

PRESS

BUT

T O

 

N

WAIT

FOR

ANSW ER

Содержание KETS 1141

Страница 1: ... Guide KETS 1141 Titan Illuminated Crossing Telephone WARNING THIS TELEPHONE REQUIRES A SPECIFIC SET UP PROCEDURE DETAILED IN THIS MANUAL PHONES MAY FAIL TO OPERATE IF NOT SET UP CORRECTLY ON INSTALLATION GAI TRONICS 1 2 3 Press LIFT HANDSET PRESS BUT TO N WAIT FOR ANSWER ...

Страница 2: ...2 KETS 1141 Titan Illuminated Crossing Telephone ...

Страница 3: ... 6 5 Operation Testing 7 6 Installation 8 6 1 General 8 6 2 If glands are required 8 6 3 Wall mounting 9 6 4 Pole mounting 10 7 Connections 12 8 Legend Panel 13 8 1 Legend panel dimensions 13 8 2 Fitting the legend panel 14 9 Cleaning 14 9 1 Normal Cleaning 14 9 2 Stainless Steel Push button 14 9 3 Graffiti 14 10 Aftercare 15 11 Technical Specifications 16 12 CE Declaration 18 ...

Страница 4: ...case or installing If in doubt disconnect the telephone line elsewhere before accessing the line connections For increased protection against lightning transients attach a local earth to the main terminal block see section 7 2 Product Description This manual describes the KETS 1141 model Titan telephone designed for use on KETS Kestrel Emergency Telephone System at automatic half barrier AHB level...

Страница 5: ...ETS 1141 Titan Illuminated Crossing Telephone 5 2 1 At a Glance 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Door Handset Pushbutton Faceplate Illuminated panel KETS product identity label Brown ...

Страница 6: ...ue address on the system 4 Addressing Procedure To make sure that a KETS phone automatically acquires the correct address the rules are simple 1 Only apply power to a phone when the handset is OFF HOOK 2 Always test ALL phones at a crossing before leaving site even if only a single unit has been changed These rules apply equally to a complete new crossing installation or replacement of a unit or u...

Страница 7: ... unique address Note this situation can only occur as a result of maintenance activity not during normal operation or as a result of power or line interruption 5 Operation Testing Normal operation of the phone is as follows Open the door the illumination panel will come on Lift handset dial tone is heard but the call does not start Press button ring tone is heard until the call is answered The cal...

Страница 8: ...ey is required 2 Line connections are on the reverse of the faceplate on the lower edge of the PCB as it protrudes from the back box 3 The Titan telephone is intended for vertical installation to a wall or pole Select the required mounting method section 6 and mount the rear enclosure first where applicable 4 Route the required cable through a gland as appropriate 5 Make sure the handset is off th...

Страница 9: ...is compressed against the enclosure surface 4 Proceed with chosen mounting method below As standard the telephone is supplied with a pole mounting kit part number 100 02 0208 001 6 3 Wall mounting 1 Using a suitable tool punch out 4 holes in the rear enclosure taking care not to damage or dislodge the plastic bushes Only four of the eight holes are required the outer ones are recommended The inner...

Страница 10: ...mplate for drilling 3 Drill holes in the wall on the marked positions Select appropriate screws wall plugs etc for the type of wall bearing in mind that the weight of the complete phone is around 5kg IMPORTANT Check that screws seat properly in the plastic bushes to ensure a watertight seal Do not use excessive tightening force as this may crack the case 4 Ensure that all four plastic flanged bush...

Страница 11: ... the rear enclosure using the M6 x 25 screws provided pushing the screws through from inside the phone 3 Tighten nuts to a torque of 4 5Nm max IMPORTANT avoid the use of power tools Spinning the nuts too quickly can cause a rapid increase in heat which can cause the nuts to seize as a result of galling or cold welding Note only use the outer four holes and ensure that the screws seat properly in t...

Страница 12: ...he second position must be left in place Connect the telephone line A and B to the main terminal block TB2 as shown The centre earth terminal is intended as an optional connection to a local earth for the purpose of enhanced protection from lightning transients and is not required in terms of user safety from the telephone network Note Conductor sizes to be 0 5mm 2 5mm2 flexible cable 0 5 4 0mm2 s...

Страница 13: ...osure The legend panel is then backlit by the illuminated panel 1 2 3 Press LIFT HANDSET PRESS BUTTON WAIT FOR ANSWER Variable Information Replaceable Legend Panel Fixed Information 8 1 Legend panel dimensions The legend panel should be made from clear material for example laser printer OHP film preferably 0 5mm thick max 1mm and cut to the template below AREA FOR TEXT 90 66 81 83 2 1 Note that th...

Страница 14: ...ng a tab for ease of removal It must not overlap the strip of gasket otherwise the water seal will be compromised 9 Cleaning Recommended cleaning methods are outlined below 9 1 Normal Cleaning For normal cleaning we recommend Virosol manufactured by Clover products Carefully follow manufacturer s instructions for storage handling and use 9 2 Stainless Steel Push button The stainless steel push but...

Страница 15: ... installation and commissioning packages and technical support from ad hoc repairs to full maintenance contracts By choosing GAI Tronics as your aftercare provider you are ensured of manufacturer expertise and ISO 9000 certified quality control standards throughout the life of the product We can also supply a full range of accessories including mounting posts beacons and high volume sounders Conta...

Страница 16: ...line power Hookswitch Electronic with no external moving parts Ringer loudness 75dBA 1m Handset Suitable for inductive coupling to Hearing Aids having a T switch position Tested to ETS 300 381 Environmental limits Temperature Operating 20ºC to 60ºC Storing 40ºC to 70ºC Relative Humidity Up to 95 non condensing Ingress Protection IP65 to EN60529 Degrees of protection provided by enclosures Physical...

Страница 17: ...y equipment including electrical business equipment Recycling Information The symbol shown here and on the product means that the product is classed as Electrical or Electronic Equipment and should not be disposed with other household or commercial waste at the end of its working life The Waste of Electrical and Electronic Equipment WEEE Directive has been put in place to recycle products using be...

Страница 18: ...18 KETS 1141 Titan Illuminated Crossing Telephone 12 CE Declaration ...

Страница 19: ...KETS 1141 Titan Illuminated Crossing Telephone 19 ...

Страница 20: ...n of Hubbell Ltd Brunel Drive Stretton Park Burton on Trent DE13 0BZ England Tel 01283 500500 Fax 01283 500400 www gai tronics co uk The policy of GAI Tronics is one of continuous improvement therefore the Company reserves the right to change specifications without notice ...