KETS 1141 Titan Illuminated Crossing Telephone
7. Connections
If glands are used, insert the cable through the gland body and tighten the gland nut
sufficiently to clamp the cable, making a seal. Ensure sufficient cable is left to allow
removal of the faceplate without straining the cable.
IMPORTANT
: If only one cable entry is used, the BLACK blanking plug fitted to
the second position must be left in place.
Connect the telephone line A and B to the main terminal block TB2 as shown.
The centre earth terminal is intended as an optional connection to a local
earth for the purpose of enhanced protection from lightning transients, and is
not required in terms of user safety from the telephone network.
Note:
Conductor sizes to be 0.5mm-2.5mm
2
(flexible cable);0.5-4.0mm
2
(solid cable) The terminal block can be disconnected from the circuit board
for easier installation
Cabling must not infringe European Low Voltage Directive (LVD)
2006/95/EC.