Installation Instructions
VSet 12 / VSet6 / VSet1 Phonesets
Models:
2001-00294 VSet6 — Software: v1.1
2001-00295 VSet1 — Software: v1.1
2001-00281 VSet12 — Software: v1.1
For use with:
2001-00343 Hx6 POTS+AES Digital Talkshow System
2001-00342 Hx6 POTS Digital Talkshow System
2001-00307 VX Engine
2001-00256 IQ6 Telco Gateway ISDN (Non-US)
2001-00255 IQ6 Telco Gateway ISDN (US)
2001-00248 iQ6 Telco Gateway POTS
Thank you!
We appreciate your purchase of a Telos broadcast phone product. This sheet
gives you brief setup instructions for the VSet phones. The manual that comes
with your VX Engine, iQ6 Telco Gateway, HX6 Digital Talkshow System gives
detailed descriptions of the phone system, including operating instructions
for this VSet, and what your network needs to support it. Questions? Call us at
+1-216-241-7225.
Telos Systems, a Telos Alliance Company
1241 Superior Avenue E.
Cleveland, Ohio, USA 44114
http://www.Telos-Systems.com
Before You Begin...
Your new Telos VSet phone is designed for fast, intuitive
control of Telos VX and iQ6 Talkshow Systems. Please
confi
gure your Telos phone system according the
instructions in the User Manual before connectiong your
VSet to the network.
VSet phones receive 48-volt power through their Ethernet
connection, allowing PoE (Power over Ethernet) to be
supplied by Ethernet switches equipped to provide it.
If your Ethernet switch does not have PoE capability,
please use the PoE injector included with your VSet. The
PoE adapter is also required for non-switched direct,
connections to the HX6 Digital Talkshow System.
Connect Your VSet
•
Determine whether your system’s Ethernet switch pro-
vides PoE. If so, connect one end of the supplied Eth-
ernet cable to one of your switch’s PoE-enabled ports,
and the other to your VSet.
OR:
•
If your switch does not have PoE capability, connect
the included PoE Injector to the supplied Ethernet
cable. Connect one end of the cable to your Ethernet
switch, and the other to your VSet.
A direct, non-switched connection between the HX6
and a VSet is possible without use of a cross-over cable.
Standard ethernet cables from the HX6 between the PoE
power supply and both the HX6 and VSet are acceptable.
Note: In factory default confi gurations, the IP addresses
between a VSet and an HX6 should default to directly
compatible settings.
The LED indicators near the VSet connection port should
show solid green (good connection); the yellow LED should
be fl ashing, indicating data fl ow. After a few seconds, the
VSet’s LCD screens will light. If they do not, check the
connection of the PoE Injector and / or Ethernet cable.
Assign an IP Address
Press the
Menu key and fi nd the
Setup
option.