Ac Output
Ingecon®Sun
15U 208
15U 480
25U 208
25U 480
Output power factor rating
>0.99
Operating voltage range
(ac) (L-L)1
183 - 229
V ac
422.5 - 528
V ac
183 - 229
V ac
422.5 - 528
V ac
Operating frequency range
59.3 - 60.5 Hz
Number of phases
3F + N
Nominal output voltage (ac) 208 V
480 V
208 V
480 V
Normal output frequency
60 Hz
Maximum continuous
output current ac per line
41.6
18
69.4A
30.1 A
Power
15 kVA
(15 kW)
15 kVA
(15 kW)
25 kVA
(25 kW)
25 kVA
(25 kW)
Maximum output fault
current (ac) and duration
159A @
9.6ms
74A @ 9ms
206A @
11.2ms
266A @
8.8ms
Maximum output
overcurrent protection
70 A
30 A
100 A
50 A
Utility interconnection
voltage and frequency
trip limits and trip time
accuracy.
Trip limit
and trip time
accuracy
Voltage:
+/-1%
Frequency:
+/-0.1 Hz
Time
0.060 secs
Normal operation
temperature range
-15 - +55°C
Maximum full power
operating ambient
+55°C
+45°C
Enclosure Rating Type
3R
Installation and Operation Manual
INGECON
®
SUN SMART U
AAS2000IKI05
AAS2000IKI05
Rev. _
Date: February 2011
Page 19