TK 56171-2-OP-EN
127
Figure 141.
Multi-Temperature Loading Considerations
1.
Correct load height (trailers
without chutes)
6.
Interior/exterior walls and insulation in
good condition
2.
Tight doors and gaskets
7.
Clear defrost drains
3.
Center bulkhead with tight air
seals (multiple compartment
trailers)
8.
Unit inspection
4.
Good air circulation around load
9.
Good outside air circulation
5.
Proper cargo temperature prior to
loading
10.
Tight air seals between unit and trailer
Single Temperature Loading Procedures
Additional steps must be taken to insure load temperature requirements are
implemented and maintained when a multi-temp unit is used to refrigerate a
single-temperature load. Trailer loading procedure will be different
depending on how temperature control has established for each trailer
compartment Zone. Refer to (
“Operating the Unit in Single Zone Control
) in the Operating Instructions chapter in this manual.
In the example (
), each Zone could be individually set to
35°F. The evaporator in each compartment will then control the temperature
in that compartment to the same 35°F setpoint.