TK 56171-2-OP-EN
79
Shutdown Alarm
If a Shutdown Alarm occurs while the unit is running, it will be indicated by
all of the following (
):
•
The Alarm Icon will appear.
•
The display, backlight, and optional remote alarm light will flash on and
off.
•
The display will alternate from normal to inverted and back (light areas
become dark and dark areas become light).
Shutdown Alarms will force the unit into shutdown. The unit will remain in
shutdown until the Shutdown Alarm is manually cleared. Exceptions are
some engine and electric Shutdown Alarms that become Log Alarms when
switched to the alternate operating mode (diesel to electric or electric to
diesel). The TemperatureWatch screen is disabled if a unit level Shutdown
Alarm is active.
Figure 85.
Shutdown Alarm Screen
Unit Level Shutdown Alarm
Unit Level Shutdown Alarms will force the unit into shutdown. The unit will
remain in shutdown until the Shutdown Alarm is manually cleared.
Exceptions are some engine and electric Shutdown Alarms that become Log
Alarms when switched to the alternate operating mode (diesel to electric or
electric to diesel). The TemperatureWatch screen is disabled if a Unit Level
Shutdown Alarm is active.
Zone Level Shutdown Alarm
A zone Shutdown Alarm will force the affected zone to shutdown, but allow
the unit to continue to run as required by the host unit or other zones. A
small alarm icon will appear next to the affected zone and blink with a period
of half second on - half second off. If zone Shutdown Alarms occur in all