118
TK 56171-2-OP-EN
Table 1.
Table of Alarm Codes (continued)
COLOR CODE
DEFINITIONS:
OK TO
RUN
CHECK AS
SPECIFIED
TAKE IMMEDIATE
ACTION
Num
Description
Operator Action
33
Check Engine RPM
Report alarm at end of day.
35
Check Run Relay Circuit
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
(36)
Electric Motor Failed to Run
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
37
Check Engine Coolant Level
Check engine coolant level. Do not
remove the cap if the engine is hot.
Report alarm at end of day.
38
Electric Phase Reversed
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
39
Check Water Valve Circuit
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
40
Check High Speed Circuit
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
41
Check Engine Coolant
Temperature
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
42
Unit Forced to Low Speed
Report alarm at end of day.
43
Unit Forced to Low Speed
Modulation
Report alarm at end of day.
44
Check Fuel System
Add fuel as necessary, otherwise
report alarm at end of day.
45
Check Hot Gas or Hot Gas
Bypass Circuit
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
46
Check Air Flow
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.