REMOTE STANDBY/OFF INPUT:

WIRE NORMALLY OPEN (N.O.) MOMENTARY SWITCH ACROSS DELAYED EGRESS MODULE TERMINALS 2 AND 5.

FUNCTION

UPON MOMENTARY CONTACT CLOSURE, DELAYED EGRESS MODE
BECOMES INACTIVE, DEVICE OPERATES AS A STANDARD EXIT
DEVICE, AND GREEN DEVICE LED FLASHES.

NORMALLY OPEN (N.O.)

MOMENTARY CONTACTS

1 2 3 4

5 6 7 8

9 1011

LOCAL BYPASS INPUT:

WIRE NORMALLY OPEN (N.O.) MOMENTARY SWITCH ACROSS DELAYED EGRESS MODULE TERMINALS 1 AND 5.

NORMALLY

OPEN (N.O.)

MOMENTARY

CONTACTS

1 2 3 4

5 6 7 8

9 1011

FULL

CLOCKWISE

BYPASS = 1 SEC.

FULL COUNTER-
CLOCKWISE
BYPASS = 16 SEC.

POTENTIOMETER

SETS BYPASS

TIME

FUNCTION

UPON MOMENTARY CONTACT CLOSURE, DURING DELAY TIME
DELAYED EGRESS MODE BECOMES INACTIVE, DEVICE OPERATES
AS A STANDARD EXIT DEVICE, AND GREEN DEVICE LED FLASHES.

CONDITION

CONTROL MODULE AND DEVICE LEDS

HORN

MAGNET

POSSIBLE SWITCHED CONDITION CHANGES

FIRE ALARM

OFF

OFF

OFF

ARMED

CONTACT OPEN

ARMED

SOLID GREEN

OFF

ON

SW1 TO BYPASS; SW2 TO LOCAL BYPASS; TOUCHBAR SW TO NUISANCE

LOCAL BYPASS

FAST FLASHING GREEN

OFF

OFF

SW1 NO CHANGE; SW2 NO CHANGE; TOUCHBAR SW NO CHANGE

(LEGAL RELEASE)

(IF TOUCHBAR IS DEPRESSED DURING LOCAL BYPASS OR BYPASS DURING 3-15 SEC.

MODES, SYSTEM GOES INTO NUISANCE WHEN IT REARMS; ALARM DRY CONTACTS

SWITCH STATE AFTER NUISANCE DELAY UPON INITIATION OF ALARM CYCLE)

UNARMED

SLOW FLASHING GREEN

OFF

OFF

SW1 NO CHANGE; SW2 TO ARMED; TOUCHBAR SW NO CHANGE

(BYPASS)

NUISANCE

SOLID GREEN AND RED

ON

ON

SW1 TO BYPASS; SW2 NO CHANGE

(0-3 SEC.)

UNLOCK DELAY

SOLID GREEN/FLASHING RED

WARBLE

ON

BAR RELEASED: SW1 NO CHANGE; SW2 LOCAL BYPASS TO ARMED

(3-16 SEC.)

DELAY UNLOCK

SOLID RED

ON

OFF

BAR RELEASED: SW1 NO CHANGE; SW2 TO ARMED

(RELEASE)

BYPASS DURING

MEDIUM FLASHING GREEN

OFF

OFF

BAR RELEASED: SW1 NO CHANGE; SW2 LOCAL BYPASS TO ARMED

3-16 SEC. (RESETS

AFTER DELAY TIME)

Содержание Monarch 18 Series

Страница 1: ...IMS 1 QTY 4 POWER SUPPLY DEX WIRING DIAGRAM 2 0 A FUSE DELAYED EGRESS MODULE DXM 5 POWER TRANSFER HINGE 8 WIRE 1 5 A MINIMUM RATED MUST BE U L APPROVED NOTE SUPPLIED BY OTHERS 6 18 20A W G WIRE NOTE S...

Страница 2: ...3 1 1 2 490 3 4 4023 2 570 3 1 4 4 1 4 4023 2 579 2 5 8 3 5 8 4023 2 565 3 4 4023 2 490 3 1 4 4 1 4 F4023 2 F 490 3 1 4 4 1 4 F4023 2 F 570 3 1 4 4 1 4 VERTICAL C DOUBLE DOOR INSTALLATION WITH MONARCH...

Страница 3: ...0 1 2 44 1 2 DEVICE TOUCHBAR LENGTH DEVICE LENGTH LHR SHOWN SHORTTOUCHBAR W LONG CHANNEL 3 DOOR AND HARDWARE PREPARATION C DEVICE REF L CVERTICAL L 3 8 DIA HOLE 4 PLACES C DEVICE REF L C VERTICAL L 1...

Страница 4: ...IN CHANNEL COVER A DRILL 11 16 HOLE AS SHOWN BELOW LEFT B REMOVE MATERIALAS SHOWN BELOW RIGHT REMOVE BURRS X CUT OFF LENGTH Y 1 RECOMMENDED 8 3 4 MINIMUM 3 9 IF DEVICE IS LONGER THAN X USE A HACKSAW...

Страница 5: ...HROUGH DOOR SKIN ON DEVICE SIDE OF DOOR ONLY WARNING THERE ARE NO SERVICEABLE PARTS IN THE POWER SUPPLY DEX OR IN THE DELAY MECHANISM THE REQUEST TO EXIT SWITCH INSIDE THE DEVICE IS PRESET AT THE FACT...

Страница 6: ...LL MORTISE CYLINDER UPSIDE DOWN 4 7 INSTALL INTERFACE BOARD TO CYLINDER BRACKET 6 32 X 1 4 PPHMS 4 PLACES LHR SHOWN 4 8 SLIDE CHANNEL COVER HALF WAY INTO CHANNEL 4 9 CONNECT COILCONNECTOR TO INTERFACE...

Страница 7: ...NTING BRACKET INTO CHANNEL MOUNTING BRACKET SEX BOLT 1 4 20 X 3 4 TPHMS MOUNTING SCREW CAUTION BE CAREFUL NOT TO PINCH OR CUT WIRES DURING INSTALLATION INTERFACE BOARD CABLE 4 14 MOUNT POWER SUPPLY DE...

Страница 8: ...MAGNET 24 VDC 4 BLACK COMMON 5 YELLOW GREEN LED 6 ORANGE RED LED AUDIBLE 7 N A DRY ALARM CONTACT COM 8 N A DRY ALARM CONTACT N O 9 N A DRY ALARM CONTACT N C 10 WHITE LEDS AUDIBLE 24 VDC 11 WIRE COLOR...

Страница 9: ...ENTER PUNCH DRILL AND TAP STRIKE MOUNTING SCREW HOLES 4 21 INSTALL STRIKE LHR SHOWN L L DIM A DEVICE REF C L 10 24 X 3 4 FPHMS 3 PLACES 570 STRIKE SHOWN DIM B STRIKE DIM A DIM B 570 2 2 490 2 1 1 2 56...

Страница 10: ...TIMES NUISANCE ALARM DEPRESS THE TOUCHBAR FOR LESS THAN 3 SECONDS THEN RELEASE THE LED IS SOLID GREEN AND RED AND HORN SOUNDS A MONOTONE AT THIS TIME THE DELAY EGRESS PROCESS HAS NOT STARTED AND THE D...

Страница 11: ...HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CANNOT BE RE HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CANNOT BE RE HANDED DOUBLE CYLINDER AND ELECTRIC LOCKING TRIM DEVICES CAN...

Страница 12: ...ING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING TO CHANGE FROM STANDARD LOCKING TRIM TO LESS LOCKING 1 1 1 1 1 REMOVEBACKPLATESUB ASSEMBLY...

Страница 13: ...CONTACTS FIRE ALARM JUMPER FUNCTION EXIT DEVICE UNLOCKS IMMEDIATELY UPON A FIRE ALARM ALARM DRYCONTACTS 1 ATTACH COMMON COM WIRE TO DELAYED EGRESS MODULE TERMINAL 8 2 ATTACH NORMALLY OPEN N O WIRE TO...

Страница 14: ...E AND DEVICE LEDS HORN MAGNET POSSIBLE SWITCHED CONDITION CHANGES FIRE ALARM OFF OFF OFF ARMED CONTACT OPEN ARMED SOLID GREEN OFF ON SW1 TO BYPASS SW2 TO LOCALBYPASS TOUCHBAR SW TO NUISANCE LOCALBYPAS...

Страница 15: ...1 13 16 3 7 8 7 3 4 2 13 16 3 3 16 DEVICE REF C L DX F 18 R DRILLING TEMPLATE RHR VERTICAL C L 3 1 8 1 9 16 5 8 DIA HOLE x 1 2 DEEP E 1 1 4 DIA HOLE B 5 8 DIA HOLE x 1 2 DEEP E DRILLAND TAP FOR 10 24...

Страница 16: ...HOLE D 1 4 2 1 2 1 13 16 3 7 8 7 3 4 2 13 16 3 3 16 DEVICE REF C L DX F 18 R DRILLING TEMPLATE LHR VERTICAL C L 1 9 16 3 1 8 5 8 DIA HOLE x 1 2 DEEP E 5 8 DIA HOLE x 1 2 DEEP E DRILLAND TAP FOR 10 24...

Отзывы: