D-1400-4 Page 10 of 16
5
OPERATIONAL TEST
TO BYPASS DELAYED
EGRESS FEATURE:
1.
TURN KEY CLOCKWISE
UNTIL IT STOPS.
2.
LED FLASHES GREEN
AND HORN WILL NOT SOUND.
3.
RETURN KEY TO INITIAL
POSITION AND REMOVE KEY.
4.
DEVICE FUNCTIONS AS A
NORMAL EXIT DEVICE.
LHR
SHOWN
TO ARM DELAYED
EGRESS FEATURE:
1.
TURN KEY COUNTERCLOCK-
WISE UNTIL IT STOPS.
2.
LED IS SOLID GREEN AND
HORN WILL NOT SOUND.
3.
RETURN KEY TO INITIAL
POSITION AND REMOVE KEY.
4.
DEVICE IS ARMED.
TOUCHBAR
CYLINDER
LED
HORN
TO TEST DELAYED EGRESS FEATURE:
DEPRESS TOUCHBAR FOR THE FOLLOWING TIMES:
NUISANCE ALARM:
DEPRESS THE TOUCHBAR FOR LESS THAN 3 SECONDS, THEN RELEASE. THE LED IS
SOLID GREEN AND RED AND HORN SOUNDS A MONOTONE. AT THIS TIME, THE DELAY EGRESS PROCESS
HAS NOT STARTED AND THE DELAY SYSTEM IS ARMED.
DELAY EGRESS PROCESS:
DEPRESS TOUCHBAR FOR MORE THAN 3 SECONDS. THE IRREVERSIBLE
DELAY EGRESS PROCESS STARTS. THE LED IS SOLID GREEN AND FLASHING RED AND THE HORN
SOUNDS AN OSCILLATING TONE. AFTER 15 SECONDS, THE DEVICE RELEASES AND FUNCTIONS AS A
NORMAL EXIT DEVICE. THE LED IS SOLID RED AND THE HORN SOUNDS A MONOTONE.
TO BYPASS FIRE
ALARM FEATURE:
1.
TURN KEY COUNTER-
CLOCKWISE UNTIL IT STOPS.
2.
DISCONNECT CONTACTS ON
FIRE ALARM CIRCUIT AT POWER
SUPPLY (SEE PAGES 8 AND 13).
3.
EXIT DEVICE OPENS WITHOUT
DELAY AND LED IS OFF.