3) PREPARE HOLES FOR DEVICE, STRIKE AND LATCHES. AFTER DRILLING HOLES, REMOVE THE DRILLING TEMPLATE.
DRILL 3/8" DIAMETER HOLES ON TRIM SIDE OF DOOR ONLY (SEE DIAGRAM BELOW).
4) IF USING OUTSIDE TRIM, PREPARE DOOR USING SEPARATE TRIM DIRECTION SHEET. FOR SEXBOLT INSTALLATIONS,
CL
A) LOCATE VERTICAL ON DOOR.
B) MEASURE DISTANCE "Y" FROM VERT. TO STOP SURFACE ON HINGE SIDE.
C) SUBTRACT 1" FOR RECOMMENDED CLEARANCE (FOR DOOR STILES LESS THAN 2-3/4" WIDE, SUBTRACT 3/4").
D) LENGTH OF DEVICE FROM VERT. TO CUT-OFF LENGTH IS "X".
CL
CL
5) DETERMINE DEVICE LENGTH.
NOTE:
FOR STANDARD DOGGING: 3" MIN.
FOR CYLINDER DOGGING: 5" MIN.
FOR EXIT ALARM & ELECTRIC DOGGING: 7-1/2" MIN.
PAGE 4
LHR SHOWN
TRIM SIDE OF DOOR
DEVICE SIDE OF DOOR
1” RECOMMENDED
SEE
NOTE
BELOW
“X”
CUT-OFF LENGTH
VERT CL
“Y”
1/4"
3/8" DIA. HOLE
(2 HOLES)
9/32" DIA. HOLE
(2 HOLES)
1/4"
DEVICE REF CL
DEVICE REF CL
VERT C C MOUNTING
L L
MOUNTING C C VERT
L
L
12) INSTALL ROD GUIDE COVER.
A) SLIDE ROD GUIDE INSERT INTO ROD GUIDE BRACKET.
B) PLACE ROD GUIDE COVER OVER ROD GUIDE INSERT.
C) INSTALL ROD GUIDE COVER TO ROD GUIDE BRACKET USING #8-32x1/4" UFPHMS (2 QTY, PER ROD GUIDE).
PAGE 13
#8-32x1/4" UFPHMS (2 QTY)
ROD GUIDE COVER