background image

 

 

 9  

 

R

e

v

is

n

: 0

5

   

  R

e

f.:

 M

A

N

U

_

V

B

Z

   

 1

6

/0

2

/2

0

1

7

 

After  every  cycle,  the  water  generated  is  routed  to  a  pan  on  the  rear  of  the  unit  and  is 

evaporated  by  the  heat  given  off  by  the  compressor  except  to  VBZ  where  this  pan  must  be  removed 

manually.  

 

The defrost timer is located on the condensing unit, in the back of the cabinet.  

 

 

 

 

Starting a Manual Defrost Cycle 

If manual defrost is required, you may push the 

DEF

 key for more than 2 seconds and a manual 

defrost will start. 

 

Adjusting Interval between Defrost Cycles (IdF)

 

The defrost cycles are performed periodically at an interval of: Ice Cream cases (VBZ) = 5h. This 

interval starts being counted from the end of the previous count. The duration of the defrost therefore 

does  not  affect  then  the  interval  between  defrost  cycles.  The  parameter  that  controls  the  interval 

between defrosts cycles is: 

IdF: Determines the time interval between the beginning of two defrost cycles. 

To adjust this parameter, you may follow the next instruction: 

 

1. Enter the Programming mode by pressing the 

SET + DOWN

 keys for 3s (the “

°C” or “°F” 

LED 

starts blinking). 

2. Select the required parameter: 

IdF

. Press the 

SET

 key to display its value 

3. Use 

UP

 or 

DOWN

 to change its value. 

4. Press 

SET

 to store the new value. 

To exit

: Press 

SET + UP 

or wait 15s without pressing a key. 

NOTE

: the set value is stored even when the procedure is exited by waiting the time-out to expire. 

 

Important: 

To  ensure  regular  defrosts,  the  interval  between  defrost  cycles  must  be  greater  than  the 

maximum defrost duration, plus the dripping time and post-dripping time. 

 

Adjusting the Maximum Defrost Duration (MdF) 

This  parameter  determines  the  maximum  defrost  duration  on  the  evaporator  in  minutes  if 

defrost  by  temperature  is  selected.  If  timed  defrost  has  been  selected,  this  represents  the  actual 

duration of the defrost selected. You may follow the last instruction, but the parameter that has to be 

changed in this case is 

"MdF"

. The default value is: Ice Cream cases (VBZ) = 15 minutes. 

DEF key 

DOWN key  

UP key 

Содержание VBZ Ibiza

Страница 1: ...VBZ Ibiza Cases GELATO DISPLAY CASES Service Installation Manual...

Страница 2: ...CEDURE 7 8 OPERATION 7 8 1 Temperature control adjustment 7 8 2 Defrost control 8 8 3 Loading product 10 9 MAINTENANCE CARE AND CLEANING 10 9 1 Cleaning procedure 10 9 2 Parts and Service Error Marcad...

Страница 3: ...cluding the following This refrigerator must be properly installed and located in accordance with this manual before it is used Do not allow children to climb stand or hang on the shelves in the refri...

Страница 4: ...nt This unit is intended for indoor use only Be sure the location chosen for your unit must be able to provide good air circulation for most efficient refrigeration Avoid locations near heat sources s...

Страница 5: ...front side or back However you must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before plugging it in so that the compressor oil and refrigerant may...

Страница 6: ...e should be checked before connection to assure that proper voltage for the cabinet wiring is available To determine correct unit voltage please refer to the serial data plate located on an inner wall...

Страница 7: ...ercial standards If any unusual noises are heard turn the unit off immediately and check for any obstructions of the fans All cabinets must be given enough time to reach normal operating temperature b...

Страница 8: ...Menu mode it is used to look through the parameter codes or decrease the value of the variable in use This turns the light on and off Note while in the OFF status the light button is active VBZ ice c...

Страница 9: ...wo defrost cycles To adjust this parameter you may follow the next instruction 1 Enter the Programming mode by pressing the SET DOWN keys for 3s the C or F LED starts blinking 2 Select the required pa...

Страница 10: ...binet Do not leave food inside the unit when it is going to remain shut down either from a power outage or fault in the equipment If the cabinet is going to remain shut down for prolonged periods try...

Страница 11: ...st be able to freely circulate through the condenser so the surface of the condenser must be kept free of dirt and grease for proper system operation Dirty condensers result in compressor failure and...

Страница 12: ...to back up and overflow the drain pans Many operating problems are derived from causes that can be easily eliminated without the need to contact the Technical Department The following page shows a ta...

Страница 13: ...ective 3 Overload protector defective 4 High head pressure 5 Fan motor pump etc wire to wrong of overload protector Compressor starts but immediately cuts out on overload 1 Starting relay contacts poi...

Страница 14: ...Fixture doors left open too long 8 Insufficient defective or water logged insulation 9 Evaporated oil logged Noisy unit 1 Compressor oil charge low 2 Fan cable on condenser or evaporator bent causing...

Страница 15: ...r authorization by Infrico In addition to the warranty set above Infrico warrants the hermetically and semi hermetically sealed compressor part only for an additional four 4 years based on the install...

Страница 16: ...pparatus is not functioning correctly users must make the checks indicated in the manual and if the problem persists contact their distributor This certificate must be presented if it is necessary for...

Страница 17: ...improper or non compliant installation of the apparatus connection voltage power supply fluctuations electrical connection not conforming to instructions etc or from manipulation of the nameplate or o...

Страница 18: ...___________ Compressor No __________________________ Vendor Signature Purchaser Signature R E T U R N T O T H E M A N U F A C T U R E R User ___________________________________________________________...

Страница 19: ...Infrico SL CR CO 762 Los Piedros Las Navas s n 14900 Lucena C rdoba Espa a 00 34 957 59 51 16 office 00 34 957 59 51 06 fax asistenciatecnica infrico com info infrico com www infrico com...

Отзывы: