Congratulations on your purchase. This refrigerator has been manufactured under strict quality 

controls and meets the high standards set by Infrico. Before shipping, each individual cabinet has been 

tested in order to assure a quality product. Furthermore, it has been produced with recyclable materials 

using  an  environmentally  friendly  process,  making  an  active  contribution  to  the  preservation  of  our 

environment.  

To  get  to  know  all  the  benefits  of  your  new  equipment,  please  read  this  instruction  manual 

carefully before installing. 

 

WARNING! Use this unit only for its intended purpose as described in this manual. 

 

When  using  electrical  appliances,  basic  safety  precautions  should  be  followed,  including  the 

following: 

 

This  refrigerator  must  be  properly  installed  and  located  in  accordance  with  this  manual  before  it  is 

used. 

 

Do not allow children to climb, stand or hang on the shelves in the refrigerator. They could damage 

the refrigerator and seriously injure themselves.  

 

Do not touch the cold surfaces in freezer compartments when hands are damp or wet. Skin may stick 

to these extremely cold surfaces. 

 

Do not store or use flammable products near the refrigerator. 

 

Unplug the refrigerator before cleaning and making repairs. 

 

NOTE: We strongly recommend that any servicing be performed by a qualified technician. 

 

The  serial  data  plate  is  a  permanently  affixed  label  which  has  important  electrical  and 

refrigeration data about your product, as well as the model and serial number. This label is located in 

the interior compartment on all standard models. 

 

 

 

Serial Number

 

 

 

 

1

 

GENERAL INFORMATION 

2

 

SAFETY PRECAUTIONS 

3

 

SERIAL DATA PLATE 

Содержание VBZ Ibiza

Страница 1: ...VBZ Ibiza Cases GELATO DISPLAY CASES Service Installation Manual...

Страница 2: ...CEDURE 7 8 OPERATION 7 8 1 Temperature control adjustment 7 8 2 Defrost control 8 8 3 Loading product 10 9 MAINTENANCE CARE AND CLEANING 10 9 1 Cleaning procedure 10 9 2 Parts and Service Error Marcad...

Страница 3: ...cluding the following This refrigerator must be properly installed and located in accordance with this manual before it is used Do not allow children to climb stand or hang on the shelves in the refri...

Страница 4: ...nt This unit is intended for indoor use only Be sure the location chosen for your unit must be able to provide good air circulation for most efficient refrigeration Avoid locations near heat sources s...

Страница 5: ...front side or back However you must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before plugging it in so that the compressor oil and refrigerant may...

Страница 6: ...e should be checked before connection to assure that proper voltage for the cabinet wiring is available To determine correct unit voltage please refer to the serial data plate located on an inner wall...

Страница 7: ...ercial standards If any unusual noises are heard turn the unit off immediately and check for any obstructions of the fans All cabinets must be given enough time to reach normal operating temperature b...

Страница 8: ...Menu mode it is used to look through the parameter codes or decrease the value of the variable in use This turns the light on and off Note while in the OFF status the light button is active VBZ ice c...

Страница 9: ...wo defrost cycles To adjust this parameter you may follow the next instruction 1 Enter the Programming mode by pressing the SET DOWN keys for 3s the C or F LED starts blinking 2 Select the required pa...

Страница 10: ...binet Do not leave food inside the unit when it is going to remain shut down either from a power outage or fault in the equipment If the cabinet is going to remain shut down for prolonged periods try...

Страница 11: ...st be able to freely circulate through the condenser so the surface of the condenser must be kept free of dirt and grease for proper system operation Dirty condensers result in compressor failure and...

Страница 12: ...to back up and overflow the drain pans Many operating problems are derived from causes that can be easily eliminated without the need to contact the Technical Department The following page shows a ta...

Страница 13: ...ective 3 Overload protector defective 4 High head pressure 5 Fan motor pump etc wire to wrong of overload protector Compressor starts but immediately cuts out on overload 1 Starting relay contacts poi...

Страница 14: ...Fixture doors left open too long 8 Insufficient defective or water logged insulation 9 Evaporated oil logged Noisy unit 1 Compressor oil charge low 2 Fan cable on condenser or evaporator bent causing...

Страница 15: ...r authorization by Infrico In addition to the warranty set above Infrico warrants the hermetically and semi hermetically sealed compressor part only for an additional four 4 years based on the install...

Страница 16: ...pparatus is not functioning correctly users must make the checks indicated in the manual and if the problem persists contact their distributor This certificate must be presented if it is necessary for...

Страница 17: ...improper or non compliant installation of the apparatus connection voltage power supply fluctuations electrical connection not conforming to instructions etc or from manipulation of the nameplate or o...

Страница 18: ...___________ Compressor No __________________________ Vendor Signature Purchaser Signature R E T U R N T O T H E M A N U F A C T U R E R User ___________________________________________________________...

Страница 19: ...Infrico SL CR CO 762 Los Piedros Las Navas s n 14900 Lucena C rdoba Espa a 00 34 957 59 51 16 office 00 34 957 59 51 06 fax asistenciatecnica infrico com info infrico com www infrico com...