EonStor U16U Installation and Hardware Reference Manual
B-4
RAID Operation Specifications
B.3. RAID
Operation
Specifications
B.3.1 Configuration
Specification
RAID Levels
0, 1(0 + 1), 3, 5, 10, 30, 50, JBOD, and Non-RAID disk spanning
Host O/S
Compatibility
Host O/S Independent
Host Interface
SCSI-320
Host Channels
Pre-configured host channels
Drive Interface
Support 16 SCSI-320 drives
Drive Channels
All drive channels are pre-set and cannot be changed.
Cache Mode
Write-through or write-back; variable optimization parameters per
array
Cache Memory
Up to 1GB SDRAM with/without ECC, non-registered
Number of LUNs
Up to 32 per host ID, a maximum up to 1024 depending on system
configuration
Multiple Target
ID’s/host Channel
Yes
Aliases for target IDs
Yes
Firmware on Flash
Memory
Yes
Drive Hot-swapping
Yes; w/ transparent reset of hung drives
B.4. Drive Tray Specifications
Specification
Tray Pitch
27.6mm
Tray Width
< 110mm
Tray Carrier Depth
180mm
Tray Plastic Depth
30mm
Total Depth
210mm ( = 180mm + 30mm)
Key Lock
Yes
B.5. Power Supply Specifications
Specification
Dimension
265mm (D) x 107mm (W) x 42.2mm (H)
Nominal Power
460W
DC output
12.0V:
32A – 38A (peak)
5.0V:
25A
3.3V: