Chapter 3: Subsystem Monitoring
I2C Port (Enclosure Monitoring)
3-9
Parameter
Upper Threshold
Lower Threshold
+3.3V
+3.6V
+2.9V
+5V
+5.5V
+4.5V
+12V
+13.2V
+10.8V
CPU Temperature
90ºC
0ºC
Board Temperature
90ºC
0ºC
Table 3-7:
Default Threshold Values
The thresholds in
Table 3-7
are the default threshold values. The user can change these
values. To see how to change these values please refer to the
Generic Operation Manual
that came with your system.
3.6.2 Failed
Devices
If any of the following devices fail the audible alarm will be triggered.
♦
RAID Controller Modules
♦
Cooling Fan Modules
♦
PSU Modules
♦
BBU Modules
♦
Hard Drives
3.7. I
2
C Port (Enclosure Monitoring)
Figure 3-7: I2C Port
The component status of an expansion enclosure is reported through an I
2
C serial bus.
This serial bus is connected to a RAID system over the enclosure’s I
2
C port using the
included I
2
C cable.