April 10, 2013
INFODRAW TMRS User Manual v5.3
156
3-12-2 Output Switches:
The TMRS unit has 4 GPIO Output Switch ports. External peripheral devices (such as alarms,
external sirens etc.) can be connected to these output ports and then set to trigger a variety
of actions once activated. The GPIO Output Switch ports are at
TTL Level
.
To connect peripheral devices to the Output Switch Ports on the TMRS unit, you must close
a connection between the following wires on the “GPIO/PTZ cable”:
Port 1) Output 1 wire
and
GND wire.
Port 2) Output 2 wire
and
GND wire.
Port 3) Output 3 wire
and
GND wire.
Port 4) Output 4 wire
and
GND wire.
ON/OFF switching of these ports is done in the “MRS Monitor Application”. Follow these
instructions:
The statuses of the Output signals are
viewed in the TMRS device tree on the
left hand side under
“Switches”
.
Switch 1
= Output 1
Switch 2
= Output 2
Switch 3
= Output 3
Switch 4
= Output 4
Double click on a
“Switch number”
to
turn it ON/OFF.