Infinova V6812IR-H0 Series Скачать руководство пользователя страница 7

21 

4.3 Network Settings 

Click “Network” in the navigation bar, and the following interface will display: 

 

Figure 4-9 Network Settings 

8 options tabs are available: Network, FTP, SMTP, HTTPS, 

802.1X, QOS, IGMP   

and SIP.   

 

4.3.1 Network Settings 

In the Network Settings interface (as shown in the figure above), users can 
enable or disable DHCP. When it is disabled, users can set Unit IP address, 
Subnet mask, Gateway and DNS server IP address manually. 
Users can also enable/disable PPPoE in this interface. If enabled, users can set 
the user name and password.   

22 

V6812IR-H0 series camera supports heartbeat function. In SNMP settings, set 
and save the heartbeat sever IP address and Heartbeat interval, and then the 
heartbeat package will be sent to the server or client, which greatly facilitates 
the server or client to know about the camera’s network status. 

 

4.3.2 FTP Settings 

 

Figure 4-10 FTP Settings 

V6812IR-H0 series camera has the function of alarm associated with FTP 
upload (alarm triggered image snapshot). Configure server IP, user name and 
password in the FTP settings and activate FTP handling way in alarm settings, 
then alarm triggered images FTP upload can be achieved. 
 

4.3.3 SMTP Settings 

 

Figure 4-11 SMTP Settings 

23 

User needs to set mail server, recipient, etc in SMTP settings interface. 

 

Server IP

: Set mail server address. 

 

From: 

Set sender’s mail address.   

 

To: 

Mail address of recipient. 

 

CC: 

Mail address of the person copy to. 

 

Authentication

: Enable or disable authentication function. This function 

should be set according to authentication requirements of mail server. 

 

User name

: Sender’s name, it can be set according user’s needs. 

 

Password

: Set sender’s password. 

 

Note:

 there is no limit for Sender’s name and password settings. 

After setting, click “Set” Save to take effect. 
If user selects “mail” in “Alarm Settings” interface, system will send mails 
according to SMTP settings. 
 

4.3.4 HTTPS Settings 

 

Figure 4-12 HTTPS Settings 

V6812IR-H0 series camera supports HTTPS protocol. You can import the CA 
certificate in the interface. 

 

 

24 

4.3.5 802.1X Settings 

 

Figure 4-13 802.1X Settings 

V6812IR-H0 series camera supports 802.1X protocol. You have to enable 
802.1X authentication when needed. Then, select an EAP method and enter the 
user name and password.     
 

4.3.6 QOS Settings 

 

Figure 4-14 QOS Settings 

There are 4 network Qos modes to be selected: 
(1) Normal Service 
(2) Max Reliability   
(3) Max Throughput   
(4) Min Delay 
Recommend: Normal Service. 

Содержание V6812IR-H0 Series

Страница 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Страница 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Страница 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Страница 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Страница 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Страница 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Страница 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Страница 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Страница 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Страница 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Страница 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Страница 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Страница 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Страница 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...

Отзывы: