33 

For H.264 major stream, the resolution of V6812IR-H01 series comes to 
1280

×

960 and 1280

×

720; while the resolution of V6812IR-H00 series comes to 

1280

×

720. 

For H.264 minor stream, the resolution comes to 640

×

480, 320

×

240 and closed. 

The resolution of MJPEG stream will be the same as that of major stream. 

 

Frame Rate:

 the number of compressed frames produced by camera per 

second. 
The bigger the frame is, the better the image continuity will be, but the CPU 
performance is lowered. 
The smaller the frame is, the worse the image continuity will be, but the CPU 
could handle more events. 
The maximum frame rate for H.264 is 30fps. The maximum frame rate for 
MJPEG is 5fps. 
 

GOV number:

 GOV number means the ratio of I frame to P frame in 

compressed video images. 
The bigger the value is, the less the data quantity is and the less network 
resource occupancy.   
Max. GOV number can be set to 60. 
 

Bit Rate Control:

 There are 2 modes: variable rate (vbr) and constant rate 

(cbr). 
The variable rate can adjust the bandwidth that it occupies automatically 
according to the complexity of image, because the complexity of real video 
sequence keeps changing, details, speed, etc, and the variable rate setting mode 
can be used to choose how much bandwidth should be used. If the video gets 
more details and moving fast, then it takes up more bandwidth to transmit, and 
reversely it occupies less bandwidth. When the setting goes with constant bit 
rate, then the image is transmitted under a constant bandwidth.   

34 

 

Bit Rate:

 You have to set the upper limit of bit rate if “vbr” is selected; the 

stream size will be fixed if “cbr” is selected and the stream size is defined in the 
“Bit Rate”. For major stream, the bit rate can be 256~10000kbps; for minor 
stream, the bit rate can be 256~ 2000Kbps. 
 

Image Quality

: it can be set under MJPEG stream. Options: Highest, High, 

Average, Low and Lowest. The higher the image quality is, the more bandwidth 
it will occupy.   

 

35 

4.5.2 OSD 

 

Figure 4-23 

OSD settings include: Text OSD and Date OSD.   

36 

Set text display to “On” and you can set the text content and display position of 
text and date OSD.   

Context: 

6 text OSDs are available. Enter the text content in the box of Context, 

which allows up to 42 characters (lower/upper case letters and 0~9).   
X-axis &Y-axis: the title axis location. Both X-axis and Y-axis can be any of 
whole numbers from 0 to 99. 
Font Size: set the font size to be displayed. The bigger the value is, the larger 
the font size is.   
Mode: OSD mode is optional with black and reverse. The OSD characters 
feature with black fringe under black mode. While in reverse mode, the color of 
OSD characters varies according to the background brightness. For example, 
when the background is white, the OSD color will be black; and when the 
background is black, the OSD color will be white. 
After all settings finished, click “Save” button to display OSD on the video. 
To cancel OSD display, set it to “OFF” and then click the button “Save”. 

 

 

Содержание V6812IR-H0 Series

Страница 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Страница 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Страница 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Страница 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Страница 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Страница 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Страница 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Страница 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Страница 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Страница 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Страница 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Страница 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Страница 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Страница 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...