Infinova V6812IR-H0 Series Скачать руководство пользователя страница 13

45 

 

Figure 4-34 

Click “OK” button, the selected user would be deleted and the account list 
would be automatically updated. 

3. User Password Change 

Click 

  button in the account list, the dialog box of Edit User Information 

will pop up:

 

 

Figure 4-35 

Input the old password, enter the desired new password for twice and then click 
“OK” button, the following picture will appear:

 

 

Figure 4-36 

Note

: The login interface will pop up if change Super user password changed.   

Input Super user name and password in the interface to log, then the prompt 
will inform password has been edited successfully. 

46 

4.8 System Log

 

Click the “Log” option tab, the date, time and log information will appear on 
the right of the screen. 

 

Figure 4-37 

It can display 30 logs on a page. The user can turn over the pages or skip to the 
desired page by clicking the below arrows. Click “Delete logs”, a prompt will 
come out. Then, click “Yes” to clear logs. 

 

47 

APPENDIX I MAGNETIC RING FILTER INSTRUCTION   

To reduce electromagnetic interference that power supply generates, it is 
necessary to install a magnetic ring filter with the power cable of Infinova 
front-end IP device.   
 

To install a magnetic ring filter with power supply: 
Step 1:

 Open the magnetic ring filter and lead the power cable through. 

 
Step 2:

 Wire the power cable on the magnetic ring filter 3 rounds or more 

(Make sure the filter can be well closed). 

 

Step 3: 

Close the magnetic ring filter. 

 
Notice: 

The magnetic ring filter should be installed no more than 50 mm 

away from the power output connector. As shown in Figure 3, the cable 
length from A to B should be 50mm at most. 
 

           

 

Figure 1 Closed magnetic ring filter            Figure 2 Open magnetic ring filter 

 

 

Figure 3 Power cable with magnetic ring filter 

48 

APPENDIX II QUESTIONS & SOLUTIONS

 

The following table describes the symptoms causes and solutions for the 
problems. 

 

Symptoms 

Possible Causes 

Solutions 

The network 
camera does 
not perform 
initiation after 
power-on 

Wrong power connection 

Reconnect power cable 

Power supply failure 

Repair or replace power 
supply 

PCB fuse damage 

Replace the fuse 

Immediate startup after 
power-off 

Restart 10 seconds later 
after power-off 

If PoE power supply is used, 
too long transmission distance 
may make the power of the 
Power Supply Switcher 
insufficient. 

Shorten the length of the 
power supply network 
cable, or replace Power 
Supply Switcher of larger 
power 

If PoE power supply is used, 
connection to other electric 
appliance make the ground 
level not in the correct level. 

Disconnect other electrical 
appliance. 

No video signal 
displayed 

The plug-in for viewing image 
is installed incorrectly. 

Refer to the Plug-in 
Installation to reinstall it. 

Network camera’s IP address 
conflicts with other user’s IP 
address 

Set the unique IP address 

Vague image 

Manual focus is not precise 

Manually adjust the camera 
focus carefully. 

 
 

 

 

 

 

Содержание V6812IR-H0 Series

Страница 1: ...while there is no guarantee that interference will not occur in a certain particular installation situation Read this manual carefully before installation This manual should be saved for future use Important Safety Instructions and Warnings Electronic devices must be kept away from water fire or high magnetic radiation Clean with a dry cloth Provide adequate ventilation Unplug the power supply whe...

Страница 2: ...ng 1 3 System Requirement Configuration of the computer to display image and control the camera CPU Intel Pentium 4 2 4 GHz or above RAM 512 MB or greater Network Port 100M Ethernet port Operating System Microsoft Windows 7 Microsoft Windows XP IE Browser Version Microsoft Internet Explorer 6 0 or above 3 1 4 Product Model This manual is for the following models V6812IR H0165SA HD Megapixel IR IP ...

Страница 3: ...g the unit and contact your local dealer 7 This camera features AGC circuit so when the camera is applied under low illumination sensitivity will enhance automatically making images look rough which is normal 8 The camera power supply is 12VDC Be sure of the terminal correct 9 Firstly perform network settings after login Gateway IP address should be set to the IP address of the gateway that the de...

Страница 4: ... is 192 168 1 254 For normal access correctly set local IP parameters before system login Do log in the system with the default super user for the first time to run the software The default Super User is admin password admin Note Do change the password in time to secure your system 2 Install and run Control After a successful login the prompt of security warning will pop up to remind the user to i...

Страница 5: ... supports local recording Click the recording button to start recording when the button changes to click it to stop recording During local recording REC appears on the video screen Click the button 15 to enter the recording storage path Default C InfiPlayerAX Video Users can set the snap shooting and recording storage path in the video settings interface Indicate that the motion detection and priv...

Страница 6: ...e process Power off will make update fail even damage the original program or unable to update again After update successfully it needs to reboot the system There is time prompt in the web page during reboot After reboot it will skip to new web page to run new program Note Available only for the super user Factory Settings V6812IR H0 series camera provides online reset function which greatly facil...

Страница 7: ...ngs then alarm triggered images FTP upload can be achieved 4 3 3 SMTP Settings Figure 4 11 SMTP Settings 23 User needs to set mail server recipient etc in SMTP settings interface Server IP Set mail server address From Set sender s mail address To Mail address of recipient CC Mail address of the person copy to Authentication Enable or disable authentication function This function should be set acco...

Страница 8: ...ck Camera in the navigation bar to enter the interface shown as below Figure 4 17 Basic Settings 4 4 1 Basic Settings You can set the following parameters Flicker frequency 50Hz or 60Hz CVBS it automatically changes with the flicker frequency Enable or disable backlight compensation or digital WDR Exposure set scene AGC auto aperture shutter speed and manual AGC can also be set in this interface E...

Страница 9: ...ue gain 31 4 4 4 IR Settings Figure 4 21 IR mode set IR illuminators working mode Options Day Night Auto turn on or off as per ambient light Switch time in auto mode the response time for day night switch Power set the adjusting mode of illuminators power consumption Options Auto Manual In auto mode adjust illuminators brightness as per ambient light In manual mode adjust the brightness by moving ...

Страница 10: ...pies less bandwidth When the setting goes with constant bit rate then the image is transmitted under a constant bandwidth 34 Bit Rate You have to set the upper limit of bit rate if vbr is selected the stream size will be fixed if cbr is selected and the stream size is defined in the Bit Rate For major stream the bit rate can be 256 10000kbps for minor stream the bit rate can be 256 2000Kbps Image ...

Страница 11: ...nction If there is certain location within the surveillance area where operators are not allowed to see and thus Privacy Mask can be applied System covers and shields the sensitive area via Privacy Mask setting to avoid operators observing certain sensitive locations on monitor Note do turn on privacy mask function in Live View interface before privacy mask setting Figure 4 25 Privacy Mask Setting...

Страница 12: ...ing the set period of each Sunday if Everyday is selected alarm will be enabled during the set period of everyday and then set the time period Enter the start time and end time in the 24 hour format The end time must be larger than the start time 4 7 Account Settings The default super user is admin password admin Super user can add delete common user and change the password of common users Super u...

Страница 13: ... rounds or more Make sure the filter can be well closed Step 3 Close the magnetic ring filter Notice The magnetic ring filter should be installed no more than 50 mm away from the power output connector As shown in Figure 3 the cable length from A to B should be 50mm at most Figure 1 Closed magnetic ring filter Figure 2 Open magnetic ring filter Figure 3 Power cable with magnetic ring filter 48 APP...

Страница 14: ...burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to the lightning proof grounding device Additional high power lightni...

Отзывы: