Infinova V1723 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

V1700 Series 

Super Domes 
Operation/Programming Manual

 

 

 

 

 

 

 

 

 

 

 

This manual addresses operation and programming of Infinova V1700 series super domes. The domes stand out for 
their state-of-the-art precision technologies and provide a highly reliable and cost-effective solution to various 
applications. 
 
This manual applies to the following models: V1723, V1743, V1725, V1745, V1726, V1746, V1727, V1747,

 

V1728, 

V1748, V1729 and V1749. V1723, V1725, V1726, V1727, V1728 and V1729 are indoor Super Domes; while V1743, 
V1745, V1746, V1747, V1748 and V1749 are outdoor Super Domes. The model V1725/V1745, V1726/V1746, 
V1727/V1747, V1728/V1748, V1729/V1749 and V1723/V1743 have optical zoom 18X, 22X, 23X, 26X, 35X and 36X 
respectively. To distinguish these six series, the convention used in this manual is [For 18X Super Dome only], [For 
22X Super Dome only], [For 23X Super Dome only], [For 26X Super Dome only], [For 35X Super Dome only] and 
[For 36X Super Dome only]. 
 
Please familiarize yourself with the instructions and guidelines discussed in this manual before attempting to operate 
and program your super domes. 

 

Содержание V1723

Страница 1: ...26 V1727 V1728 and V1729 are indoor Super Domes while V1743 V1745 V1746 V1747 V1748 and V1749 are outdoor Super Domes The model V1725 V1745 V1726 V1746 V1727 V1747 V1728 V1748 V1729 V1749 and V1723 V1743 have optical zoom 18X 22X 23X 26X 35X and 36X respectively To distinguish these six series the convention used in this manual is For 18X Super Dome only For 22X Super Dome only For 23X Super Dome ...

Страница 2: ......

Страница 3: ...ll other trademarks that may appear belong to their respective proprietors FCC Warning The Super Domes comply with the FCC rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received including interference that may cause undesired operation The Super Domes have been tested and found to comply with t...

Страница 4: ...mmended by manufacturer z Position power source and related wires to assure they will be kept away from ground and access way z Refer all service matters to qualified personnel z Save product packaging to ensure availability of proper shipping containers for future transportation Indicates that the un insulated components within the product may carry a voltage harmful to humans Indicates operation...

Страница 5: ...g and Calling up a Preset 3 3 4 Setting and Calling up a Pattern 4 3 5 Setting and Calling up a Autopan 5 3 6 Special Operations 7 Chapter IV Menu Programming 7 4 1 Menu Navigation and Operation 7 4 2 Main Menu 7 4 3 Camera Information 9 4 4 Camera Setup 9 4 5 Setting AE Automatic Exposure Mode 10 4 6 OSD On Screen Display Setup 13 4 7 Home Position 16 4 8 Alarm Action and State 16 4 9 AUTOPAN 17 ...

Страница 6: ......

Страница 7: ...r level z The Digital Slow Shutter D S S allows the camera a considerably long exposure time of 1 1 5 second enabling it to capture more color data This also greatly enhances the camera s sensitivity z Optional 36X 35X 26X 23X 22X and 18X optical zoom lenses are provided to meet various needs Combined with an up to 12x digital zoom the maximum zoom ratio can reach 432X 420X 312X 276X 264X and 216X...

Страница 8: ... on screen menus z As an added security feature 1 alarm output is also provided to activate such auxiliary devices as time elapse recorders or digital video recorders 2 8 Wide Application Easy Installation z Different dome models are designed to meet the needs of an ever changing market of CCTV security surveillance They stand out in applications from state security to residential communities and ...

Страница 9: ...he super domes are capable of storing up to 128 such camera views The following is a brief introduction on how to define and call up a preset using the V2117 system keyboard For preset instructions on your control system please refer to relevant manuals provided with your system keyboard To set a preset view 1 Place the key switch at the PROGRAM position OPERATE PROGRAM MENU 2 Move the joystick to...

Страница 10: ... or 3 PATRN to start recording Pattern 3 or otherwise skip to step 11 7 2 SHOT OR 3 PATRN 8 Repeat step 3 to finish the course Enter 72 SHOT or 3 PATRN to save Pattern 3 9 If pattern 4 is needed Enter 73 SHOT or 4 PATRN to start recording Pattern 4 or otherwise skip to step 11 7 3 SHOT OR 4 PATRN 10 Repeat step 3 to finish the course Enter 73 SHOT or 4 PATRN to save Pattern 4 11 Place the key swit...

Страница 11: ...ers of autopan such as direction speed dwell time title can be set via AUTOPAN SET menu While the start end point and calling of autopan are programmed via Infinova V2117 system keyboards Below is the way to program and call up autopan under INFINOVA PELCO D P protocols To define the start point 1 Use the joystick to move the camera to the position that is desired as the start point 2 Place the ke...

Страница 12: ...joystick to move the camera to the position that is desired as the start point 2 Place the key switch at the PROGRAM position OPERATE PROGRAM MENU 3 Set the current position as the start point For example enter code commands 66 SHOT when use V2015 V2414 DATALINE convert to Up the Coax Up the Coax dome 6 6 SHOT 4 The following overlay messages will be displayed indicating the start point has been d...

Страница 13: ...lines on menu navigation and operation please refer to the table below Please note that these operations are made in the PROGRAM mode Operations Guidelines Access the Main Menu For INFINOVA protocol using V2117 keyboard enter 65 95 and then press SHOT key For PELCO D P Protocol using V2117 Keyboard enter 95 and then press SHOT key Position the Cursor Move the joystick in the desired direction Acce...

Страница 14: ...in z Set white balance B gain z Select focus mode M A Manual Priority 3 SET AE MODE z Set digital slow shutter Except for 18X super domes with FCB EX45CP camera z Set shutter speed z Select exposure mode z Define B W mode For 23X 26X 35X 36X super domes z B W change For 23X 26X 35X 36X super domes z Pro B W For 23X 35X super domes z Reverse current image For 23X 26X 35X 36X super domes z Mirror cu...

Страница 15: ...ut the confirming password Note If the confirming password is incorrect the system will deny return to the main menu and display the following information to require correct password setting and confirmation CURRENT S N INPUT S N 20060530001 CAMERA ID 001 PASSWORD SET CONFIRM PASSWORD PASSWORD ENABLE OFF RETURN PASSWORD NOT MATCH VER XXXXX XXXXX PASSWORD ENABLE Function Enable disable the password...

Страница 16: ...thm to automatically process the image so that the final output image may be close to what the human eyes see Under some particular situations however users can also manually adjust the white balance parameters to achieve what they consider to be the best balanced pictures Options AUTO default enable the camera to automatically make white balance MANU allow a user to manually adjust white balance ...

Страница 17: ...DSS slows the picture frame rate and enhances the camera s sensitivity in poor light environments Light sensitivity improves as the value of DSS increases Option AUTO default auto digital slow shutter function The classification of manual DSS is relating to the formats of the Super Domes Under the PAL format the range could be adjusted as follows 1 1 5 1 3 1 6 1 12 1 25 1 50 Under the NTSC format ...

Страница 18: ... conditions PRO_B W For 23X 35X Super Domes only Function Change different illumination conditions for black white color conversion Options day norm default night As illumination decreases a setting of day will cause a hard conversion from color to B W while a setting of night will cause an easier conversion from color to B W As illumination improves a setting of day will cause an easier conversio...

Страница 19: ...00 015 adjustable The default is 000 For 35X Super Domes AGC LEVEL 028 STABILIZE OFF EIS FREQUENCY 5HZ SIGNAL MODE PRGSS RETURN CAM FUNCTION Function Stabilize function could proof the image shaking when the domes re operating on the acceleration or abrupt halting condition Please note that if CAM FUNCTION is ON Digital Zoom will be affected and the digital zoom can reach 64 at the most Options OF...

Страница 20: ...YNC level of the camera Note The option could not resume default in DEFAULT SET menu CLEAR TITLE Function Clear the programmed title information of presets patterns areas and AUTOPAN Move the cursor to CLEAR TITLE and deflect the joystick rightward the following information will be displayed PRESET NO PATTERN NO AREA NO AUTOPAN RETURN ALL CLEAR ALL CLEAR ALL CLEAR CLEAR PRESET NO Function Clear pa...

Страница 21: ...ivate areas Options 001 008 for 22X 23X 35X domes 001 024 optional for 18X 26X 36X domes MASK STATUS Function Turn on off Privacy Mask function Options OFF default Turn off Privacy Mask function ON Turn on Privacy Mask function When the mask status is set to ON The other menu can be set For 22X 23X 35X domes the following sub menu can be obtained through MASK STATUS GO TO POSITION RESET MASK SET N...

Страница 22: ...OR CHECK Function Implement position emendation Options ON When dome has not passed by optical coupling for a long time and accumulative error reaches some value the dome will be complled to pass by the optical coupling and the error will be reset to proceed OFF The former verifying method is adopted When the dome passes by the optical switch position emendation is to be done AUTO When dome has no...

Страница 23: ... INPUT NO 1 2 3 4 NORMAL 1 2 3 4 BACK ACTION PRESET 001 PRESET 022 NONE NONE STATE OPEN CLOSE CLOSE CLOSE INPUT 1 2 INPUT 1 2 RETURN ACT RELAY PRESET 01 R001 PRESET 02 R001 NORMAL NO PRIORITY NO 3 4 3 4 PRESET 03 R001 PRESET 04 R001 NO NO 1 2 3 4 This sample menu indicates z Alarm Input 1 has been defined as normally open assigned with Preset 001 as its alarm action and R001 as its relay output z ...

Страница 24: ... could be used to define normal route Client could use apply to PATTERN SET menu in below list to define the pattern serial number and add appellation SET CAMERA ID CAMERA SETUP SET AE MODE OSD SETUP CONFIG HOME POSITION ALARM ACTION AND STATE AUTOPAN SET PATTERN SET AREA SET DEFAULT SET EXIT PATTERN NO TITLE RETURN 001 PATTERN 001 DISPLAY ON PATTERN NO Functions Select pattern needs to be added a...

Страница 25: ...ll as numbers from 0 to 9 are available for editing the area title Spaces can also be created to separate description words A title may contain up to 16 characters and spaces Take the following steps to edit a description title 1 Move the cursor to the first entry of the TITLE item 2 Deflect the joystick downward or upward to select a suitable character or a space 3 Move the cursor to the next ent...

Страница 26: ...n Clear most user programmed data in the domes and reset the dome system to factory default 3 SHOT DEFAULT DOME ARE YOU SURE NO To locate a boundary point precisely If an area boundary needs to be precisely located 1 Zoom out the image to get a wide view making the area appear large WIDE or RESET CAMERA Reset the camera and resume the status as powered on 2 Move the camera until the desired bounda...

Страница 27: ... WIDE OPEN CLOSE FAR NEAR please refer to users manuals of INFINOVA keyboard system Menu programming of the domes under all protocols is basically the same as that showed in Chapter Ⅳ Please follow the instructions showed on the screen during operation For Preset Autopan Pattern setup and calling up shortcut operations for special functions please refer to ChapterⅢ The following tables show the op...

Страница 28: ...281 31 35 64 1 31 35 64 74 91 93 94 96 97 100 128 SHOT OPERATE Call preset 1 31 35 64 74 91 94 96 97 100 128 69 SHOT PROGRAM Save pattern PROGRAM Set pattern 1 70 SHOT 1 PATRN OPERATE Call pattern 1 PROGRAM Set pattern 2 71 SHOT 2 PATRN OPERATE Call pattern 2 PROGRAM Set pattern 3 72 SHOT 3 PATRN OPERATE Call pattern 3 PROGRAM Set pattern 4 73 SHOT 4 PATRN OPERATE Call pattern 4 92 SHOT OPERATE Se...

Страница 29: ...t Remote Reset P 68 shot P 68 shot P 68 shot P 68 shot P 68 shot Resume Alarm manually O 63 32 shot O 63 32 shot O 32 shot O 32 shot O 32 shot O 63 shot B W to Color 88 PRESET GO O 68 shot O 88 shot O 88 shot O 88 shot Color to B W 89 PRESET GO O 69 shot O 89 shot O 89 shot O 89 shot Set 1 Pattern 70 PRESET SET F2 P 70 shot P 70 shot P 70 shot P 70 shot P 70 shot Set 2 Pattern 71 PRESET SET F2 P 7...

Страница 30: ...he keyboard to control dome cameras Press ACK key to end pattern setting Enter 1 and then press PATTERN key to call a pattern Setting and Calling Patterns When a pattern is set the screen display is provided according to CM6800 matrix switcher Enter 92 and then press PRESET key to define the start point of the AUTOPAN Enter 93 andthen press PRESET keytodefine the end point oftheAUTOPAN Enter 98 an...

Страница 31: ...nglish Synchronization Internal Built in sync generator Power synchronization Line lock Phase adjusted Mechanical Manual speed 1 90o per second Max preset speed 240o per second Pan travel 360o continuous Tilt travel 0 90o Motor stepping motor Electrical Input voltage 24VAC 12VDC Power requirements 12VDC 25W 24VAC 50W Outdoor 12VDC 15W 24VAC 25W Indoor Power surge protection Yes Environmental Opera...

Страница 32: ...NTSC 1 60s Color Mode IR Cut On 1 0 lux NTSC 1 60s PAL 1 50s 0 1 lux NTSC 1 4s PAL 1 3s 0 05Lux NTSC 1 2s PAL 1 1 5s B W Mode IR Cut Off 0 01 lux NTSC 1 4s PAL 1 3s Color Mode IR Cut On 1 0 lux PAL 1 50s NTSC 1 60s 0 07 lux PAL 1 3s NTSC 1 4s B W Mode IR Cut Off 0 15 lux PAL 1 50s NTSC 1 60s 0 01 lux PAL 1 3s NTSC 1 4s Color Mode IR Cut On 0 5 lux PAL 1 50s NTSC 1 60s 0 05 lux PAL 1 3s NTSC 1 4s 0...

Страница 33: ... been activated Recycle the power Protocol or Baud rate Dip switch settings are incorrectly chosen Proper set the Protocol and Baud rate Wrong camera ID Reset the camera ID Unit can t be controlled after successful initiation Camera is not properly called via keyboard Use the camera ID to call it Wrong video cable connection Reconnect the video cable No video signal is present Video cable broken R...

Страница 34: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V2 6 0906 ...

Отзывы: