P a g e
| 47
LT 7602 Issue No2 (07/17)
480 HD INSTALLATION INSTRUCTIONS
Spillage Test Procedure.
Light the appliance on maximum setting.
Close all the doors and windows.
After five minutes fit the smoke match within match holder and position as illustrated in Figure
13 with the head of the match just inside the inlet air channel.
Run the match along the edge of the inlet air channel. All smoke must be drawn into the inlet
channel if the spillage test is satisfactory.
If spillage occurs wait a further five minutes and repeat the test.
Repeat the test with doors open and with any extractor fans in other rooms in operation.
If spillage is detected the cause must be discovered and the fault corrected. If the fault
cannot be corrected. Disconnect the fire from the gas supply and seek expert advice.
Spillage can be caused by a restriction in the flue system, down draught or insufficient
ventilation into the room where the fire is installed.
Advise The Customer.
The glass front of this fire acts as a dress guard conforming to BS 1945 (1997) and satisfies the
heating appliance regulations (1991) however; a fireguard conforming to BS6539 (1997) must
be used to protect young children, the elderly, or infirm.
During initial “burn off”, an odour may be evident during the first few hours of use. This is due
to the surface coating on the metal work “burning off”. The odour produced is harmless and
will disappear after a short period of time.
Any debris should be cleared from the appliance.
The appliance should be serviced annually by a Gas Safe registered engineer in
accordance with the Service instruction section.
Содержание 480HD
Страница 14: ...P a g e 13 LT 7602 Issue No2 07 17 480 HD USERS INSTRUCTIONS...
Страница 17: ...P a g e 16 LT 7602 Issue No2 07 17 480 HD USERS INSTRUCTIONS...
Страница 21: ...P a g e 20 LT 7602 Issue No2 07 17 480 HD USERS INSTRUCTIONS...
Страница 25: ...P a g e 24 LT 7602 Issue No2 07 17 480 HD USERS INSTRUCTIONS...
Страница 52: ...P a g e 51 LT 7602 Issue No2 07 17 480 HD SERVICE FAULT FINDING INSTRUCTIONS Fault Finding Charts...
Страница 53: ...P a g e 52 LT 7602 Issue No2 07 17 480 HD SERVICE FAULT FINDING INSTRUCTIONS...
Страница 54: ...P a g e 53 LT 7602 Issue No2 07 17 480 HD SERVICE FAULT FINDING INSTRUCTIONS...
Страница 55: ...P a g e 54 LT 7602 Issue No2 07 17 480 HD MAINTENANCE INSTRUCTIONS Wiring Diagram Attach to oxy pilot...