4.8.5
Barometer settings
By selecting the
Barometer
configuration option from the sensor tree, the barometer settings
can be edited, as shown in Figure 27:
•
Enabled
: Enables sampling of the barometer.
•
Transmit Data & Log to Flash
: If the barometer is enabled, data is transmitted and logged
to flash when required (see Section 4.8.1 for global transmission settings and Section 4.4.1
to start a flash log).
•
Sampling Rate (Hz)
: The sampling rate of the barometer (maximum 25 Hz).
•
Range (hPa)
: Sets the pressure range the barometer can measure, which is 260-1260 hPa.
•
Calibration
: Advanced option that adjusts the scaling and offset.
Figure 27: Barometer Settings
Page 35 of 60