General Information
Each Ventis Slide-on Pump is certified by one or more certifying bodies (CBs). Certifications for the
Ventis™ Slide-on Pump, at the time of this document's publication, are listed below in Table 1. To
determine the hazardous-area classifications for which a pump is certified, refer to its label or the product
order.
Table 1.1 Certifications
Certifying
Body (CB)
Area Classifications
Standards
Approved
Temperature
Range
ATEX¹
Ex ia I Ma and Ex ia IIC T4 Ga;
Equipment Group and Category: I M1 and II 1G;
EN 60079-0:2012: +A11:2013
EN 60079-11: 2012
EN 60079-26: 2007
EN 50303: 2000
-20 °C to +50 °C
(-4 °F to +122 °F)
CSA²
Class I, Division 1, Group A B C D, T4
Ex ia IIC T4
CSA C22.2 No. 152
CSA C22.2 No. 157
CSA C22.2 No. 60079-0
CSA C22.2 No. E60079-11
-20 °C to +50 °C
(-4 °F to +122 °F)
GOST- EAC
0 Ex ia IIC T4 Х
PO Ex ia I X
GOST R 51330.0,
GOST R 51330.10,
GOST R 51330.20,
GOST 24032,
GOST 14254
-20 °C to +50 °C
(-4 °F to +122 °F)
IECEx³
Ex ia IIC T4 Ga
IEC 60079-0: Sixth Edition
IEC 60079-11: Sixth Edition
IEC 60079-26: Second Edition
-20 °C to +50 °C
(-4 °F to +122 °F)
INMETRO
Ex ia IIC T4 Ga
—
-20 °C to +50 °C
(-4 °F to +122 °F)
UL
Class I, Division 1, Groups A B C D, T4;
Class I, Zone 0, AEx ia IIC T4 Ga;
Class II, Group F G (Carbonaceous and Grain
Dust)
UL 913 8th Ed.
UL 60079-0 6th Ed.
UL 60079-11 6th Ed.
CSA C22.2 No. 157
-20 °C to +50 °C
(-4 °F to +122 °F)
China Ex
Ex ia IIC T4 Ga
GB 3836.1-2010,
GB 3836.4-2010,
GB 3836.20-2010
-20 °C to +50 °C
(-4 °F to +122 °F)
¹The EC type examination certificate is DEMKO 12 ATEX 1204290 with marking code Ex ia I Ma and Ex ia IIC T4 Ga for equipment group and category II 1G and
I M1.
¹The model Ventis Slide-on Pump (VSP) complies with relevant provisions of European ATEX directive 2014/34/EU and EMC directive 2014/30/EU. The VSP is
constructed with reference to published standards of directive 2014/35/EU, to eliminate electrical risks and fulfill 1.2.7 of ANNEX II of directive 2014/34/EU.
²The VSP is CSA certified according to the applicable CSA standards for use in Class I, Division 1 and Class I, Zone 0 hazardous locations within an ambient
temperature range of Tamb: -20 °C to +50 °C.
³The IECEx examination certificate is IECEx UL 12.0021 with marking code Ex ia IIC T4 Ga for hazardous locations with an ambient temperature range of Tamb:
-20 °C ≤ Ta ≤ +50 °C.
³The charging contact parameters are: Um = 6.2V; Ii = 1.3A.