14
Table 3.2 Equipment settings required for iNet Now live monitoring
Equipment item
(
Product Manual
part number)
Setting item
TGX Gateway
(17159042)
Ventis Pro
(17156830)
Radius BZ1
(17155915)
LENS Wireless settings
LENS Wireless
No setting required
Menu: Wireless
Setting: LENS Wireless
Value: iNet Now and Local
Menu: Wireless
Setting: Wireless Radio
Value: iNet Now and Local
LENS Wireless Group
a
Menu: LENS Wireless
Setting: LENS Group
Value: Group X
a
Menu: Wireless
Setting: LENS Wireless,
LENS Group
Value: Group X
a
Menu: Wireless
Setting: Group
Value: Group X
a
Encryption key
b
Menu: LENS Wireless
Setting: Encryption Key
Value
c
: Default or custom
Menu: Wireless
Setting: LENS Wireless,
Encryption
Value
c
: Automatic or custom
Menu: Wireless
Setting: Encryption
Value
c
: Default or custom
a
If a named LENS Group (e.g., Group A) is used, all equipment items must be set to the same LENS group
or, if available, to scan.
“
X" is
used here to indicate the value for a named group will be a single character in length; available values are letters A through J.
b
All equipment items must be set to the same encryption key. “Default" or “automatic” sets the unit's LENS Wireless to the Ind
ustrial
Scientific encryption key, and "custom" to the customer's key. If a custom key will be used, some setup is also required in iNet.