7
Power
The RGX Gateway offers a variety of operational power options.
x
The RGX can be powered solely by its rechargeable, factory-installed lithium-ion battery. This option is
well suited for
short-term
use conditions that allow for the unit to be situated, between use cycles, in a
nonhazardous location for charging.
x
The RGX can receive operational power from a compatible, customer-supplied and customer-installed
fixed DC power source. This option is suitable for
permanent
installations.
x
The RGX can receive operational power from a compatible power-supply accessory only from
Industrial Scientific; use of each accessory requires the RGX be equipped with its Intrinsic Safety (IS)
Cable Adapter. This option is well suited for use conditions that do not require permanent installation,
but demand a run time exceeding that of the factory-installed battery.
x
In a nonhazardous location only
, the RGX can draw operational power from its charging power supply.
Interior case access
The unit's interior is accessed by removing four screws from the case lid. To help restrict access, the case
features tabs to accommodate a customer-supplied lock that is suitable for the location.
The unit features two conduit-hub openings, each sealed with a factory-installed plug. The conduit-hub
plugs should
not
be removed except for permanent installations that will make use of customer-supplied
conduit-hub fixtures as needed for the connection of a compatible fixed DC power source, Ethernet cable,
or both.
Compatibilities
Instruments
Use the information supplied below to ensure gas-detection instruments are compatible with the RGX
Gateway. As needed, upgrade instrument firmware to the required version, add LENS Wireless
functionality, and refer to the instrument's product manual.
Table 1.1 RGX Gateway compatible gas-detection equipment
Instrument
Required
firmware version
LENS Wireless
required
Industrial Scientific
Product Manual
part
number
Ventis® Pro Series
V3.0 or higher
Yes
17156830
Radius® BZ1 Area Monitor
V3.0 or higher
Yes
17155915
Operational power sources
WARNING:
Only
one of the following power input ports is permitted to be connected at a given time: 12V
Charger Port, IS Power Port, or 9–30 VDC Terminal Block.
The RGX can draw operational power from its factory-installed rechargeable lithium-ion battery, which can
be charged in a nonhazardous location using the RGX charging power supply.
The operational run time for the factory-installed battery can be extended with the use of a compatible
power-supply accessory only from Industrial Scientific. Each power-supply accessory, as listed below, has
Document Number: 0000037533
DO NOT CHANGE WITHOUT THE FOLLOWING AGENCY APPROVALS(S):N/A
Modified: 2018-05-25 13:18:14 EDT
State:In Work
INDUSTRIAL SCIENTIFIC CORPORATION
Title: PRODUCT MANUAL RGX GATEWAY-EN-1
Eng:
Drawing No: 17158071-1
Drawn By: Gaygan, Nancy
Created: 2018-05-16 10:24:51 EDT
Rev: 1
Printed By: Kuzmich, Bob
Int: 1.5
Date:May 29, 2018