ELECTRICAL SAFETY (EXTENSION CORDS)

 

Use only 3-wire extension cords that have 3-prong 
grounding plugs and 3-port grounded receptacles 
that accept the product’s plug. When using a power 
tool at a considerable distance from the power 
source, use an extension cord heavy enough to 
carry the current that the product will draw. An 
undersized extension cord will cause a drop in line 
voltage, resulting in a loss of power and causing 
the motor to overheat.

 

Use the chart provided below to determine the 
minimum wire size required in an extension cord. 
Only round jacketed cords listed by Underwriter’s 
Laboratories (UL) should be used.

 

Only use 50 ft. or less, round jacketed cords listed 
by Underwriter’s Laboratories (UL).

 

When operating a power tool outside, use an 
outdoor extension cord marked “W-A” or “W”. 
These cords are rated for outdoor use and reduce 
the risk of electric shock.

Ampere rating

(on air compressor data plate)

12 - 14

Cord

Length

Wire Size (AWG)

25 ft.

NR

50 ft.

12

Used on 12 gauge - 20 amp circuit.

NOTE: AWG=American Wire Gauge

WARNING

:

 When using an extension cord, keep it clear 

of the working area. Position the cord so that it will not get 
caught on lumber, tools, or other obstructions while you 
are working with a power tool. Failure to do so can result 
in serious personal injury.

WARNING

:

 Check extension cords before each use. 

If damaged, replace immediately. Never use the air 
compressor with a damaged cord since touching the 
damaged area could cause electrical shock resulting in 
serious personal injury.

WARNING

:

 Improperly connecting the equipment-

grounding conductor can result in a risk of electrical 
shock.

CAUTION

:

 Avoid body contact with grounded surfaces 

such as pipes, radiators, ranges, and refrigerators. There 
is an increased risk of electric shock if your body is 
grounded. 

CAUTION

:

 Do not expose power tools to rain or wet 

conditions. Water entering a power tool will increase the 
risk of electric shock.

CAUTION

:

 Replace damaged cords/wiring immediately. 

Damaged cords/wiring increase the risk of electric shock.

NOTICE

:

 Use longer air hoses instead of long extension cords. Your 

air compressor will run better and last longer.

ELECTRICAL SAFETY
(ELECTRICAL CONNECTION)

This air compressor is powered by a precision built 
electric motor. It should be connected to a power supply 
that is 120 volts, 60 Hz, AC only (normal household current). 

 

Do not operate this tool on direct current (DC).        
A substantial voltage drop will cause a loss of 
power and the motor will overheat. If the air 
compressor does not operate when plugged into an 
outlet, double check the power supply.

Содержание C042I

Страница 1: ...AL 4 GALLON PORTABLE AIR COMPRESSOR Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontrac...

Страница 2: ...rate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors...

Страница 3: ...ower tool Do not use the tool while tired or under the influence of drugs alcohol or medication WARNING Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away...

Страница 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Страница 5: ...will not get caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use I...

Страница 6: ...grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper installation of the grounding plug may...

Страница 7: ...or industrial applications Rental applications render this warranty null and void Labor service calls and travel charges are not covered after the first year of ownership on stationary compressors com...

Страница 8: ...time 75 seconds Lubrication Oil lubricated Input 120V 60 Hz Single phase AC only 14 0 Amps Minimum branch circuit requirement 15 A Fuse type Time delay Net weight 66 lbs DUTY CYCLE This air compressor...

Страница 9: ...ed to drain condensation at the end of each use F Check Valve When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches...

Страница 10: ...flow of air Locate the air compressor as close to the main power supply as possible to avoid using long lengths of electrical wiring The air filter must be kept clear of obstructions which could reduc...

Страница 11: ...s not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury WARNING Do not attach th...

Страница 12: ...lting Inflator Brad Nailer Stapler Framing Roofing Nailer Impact Wrench Heavy Duty 1 2 in and 3 4 in Impact Wrench Air Ratchet Recommended Tool Use Tool Cutting Drilling Surface Prep Painting HVLP Pai...

Страница 13: ...essure must never exceed the maximum pressure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item...

Страница 14: ...e to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum Check the valve before each da...

Страница 15: ...injury NOTE Always use the minimum amount of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on mor...

Страница 16: ...coolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTE If the dra...

Страница 17: ...removed and cleaned Turn the air compressor OFF O Unplug the air compressor Unsnap the air filter cover 1 to remove Remove the air filter 2 from the air filter housing 3 Blow compressed air through t...

Страница 18: ...of the oil to drain Reattach the sight glass 5 Torque the sight glass 10 12 in lbs when re assembling Be sure the gasket is between the sight glass and the pump crankcase Refill the compressor pump w...

Страница 19: ...f pressure Release the air from the tank until the compressor restarts automatically The motor hums while running slowly or it does not run at all There is low voltage from the power source Call an el...

Страница 20: ...e or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is excessive water in the air tank Drain th...

Страница 21: ...21 industrialaircontractor com Please contact 1 888 895 4549 for further assistance Service Parts C042I AIR COMPRESSOR...

Страница 22: ...14 O ring Oil Fill Cap 1 2 4 15 Cover Crankcase 1 E108530 4 16 Baffle Crankcase 1 1 4 17 Assembly Piston 1 E107755 4 18 Eccentric 1 E107962 4 19 Screw SHC M8 X 1 25 X 25 mm 1 4 20 Crankcase 1 4 21 Sc...

Страница 23: ...M6 X 1 0 Nylon Insert 4 9 40 Base Air Filter 1 5 41 Element Air Filter 1 5 42 Cover Air Filter 1 5 43 Screw SHC M5 X 0 8 X 12 mm 4 44 Shroud 1 E107879 45 Tube 3 8 in Copper Outlet 1 6 46 Nut 3 8 in C...

Страница 24: ...35 E109763 5 Kit Air Filter 40 42 E100435 6 Kit 3 8 in Copper Outlet Tube 45 47 E109154 7 Kit 3 8 in Copper Pressure Relief Tube 49 51 E109155 8 Kit Pump Isolator 4 Pack 38 E109156 9 Kit Pump Mountin...

Страница 25: ...issing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com Retain this manual for future use Document Numbe...

Отзывы: