background image

 7 

industrialaircontractor.com

 

 

Please contact 1-888-895-4549 for further assistance.

Warranty

ONE YEAR LIMITED WARRANTY

What Does This Warranty Cover? 

MAT Industries, LLC. (the Company) warrants from the date of purchase by the original retail 

purchaser only, parts and labor to remedy substantial defects found in materials, or workmanship.  

How Long Does The Coverage Last?

  The duration of this warranty is One Year. This warranty is not transferable to subsequent 

owners.

What MAT Industries Will Do?

 MAT Industries, LLC. will cover parts and labor to remedy substantial defects due to materials and 

workmanship during the first year of ownership, with the exceptions noted below, and parts only, to remedy substantial defects due to 

material and workmanship for the remaining term of coverage with the exceptions noted below. Parts used in repair of whole goods 

or accessories are warranted for the balance of the original warranty period.

What is Not Covered Under This Warranty?

 Failure by the original retail purchaser to install, maintain, and operate said equipment in 

accordance with standard industry practices. Modifications to the product, or tampering with components, or failure to comply with 

the specific recommendations of the Company set forth in the owner’s manual, will render this warranty null and void.

The Company shall not be liable for any repairs, replacements, or adjustments to the equipment, or any costs for labor performed by 

the purchaser without the Company’s prior written approval. The effects of corrosion, erosion, surrounding environmental conditions, 

cosmetic defects, and routine maintenance items, are specifically excluded from this warranty. Routine maintenance items such as: 

oil, lubricants, and air filters, as well as changing oil, air filters, belt tensioning, etc… fall under the owner’s responsibility. Additional 

exclusions include: freight damage, failures resulting from neglect, accident, or abuse, induction motors when operated from a 

generator, oil leaks, air leaks, oil consumption, leaky fittings, hoses, petcocks, bleeder tubes, and transfer tubes.

  • If the compressor is used for commercial, industrial, or military applications, the warranty will apply for 90 days from the date of  

    purchase. Two stage compressors are not limited to a 90 day warranty when used in commercial or industrial applications. 

  • Rental applications render this warranty null and void.

  • Labor, service calls, and travel charges, are not covered after the first year of ownership on stationary compressors  

 

    (compressors without handles, or wheels). Repairs requiring overtime, weekend rates, or any other charges beyond the standard 

    shop labor rate are not covered.

  • Time required for orientation training for the service center to gain access to the product, or additional time due to

    inadequate egress.

  • Damage caused by incorrect voltage, improperly wired, or failure to have a certified licensed electrician install the compressor,    

    will render this warranty null and void.

  • Damage caused from inadequate filter maintenance.

  • Pump wear or valve damage caused by using oil not specified.

  • Pump wear or damage caused by any oil contamination.

  • Pump wear or valve damage caused by failure to follow proper maintenance guidelines.

  • Operation below proper oil level or operation without oil. 

  • Gas Engines, if product is equipped with a gas engine, see engine manual for specific engine manufacturer’s warranty coverage.  

Parts purchased separately: The warranty for parts purchased separately such as: pumps, motors, etc., are as follows:

From Date of Purchase 

  • All single & two stage pumps: 1 year

  • Electric motors: 90 days

  • Universal motor/pump: 30 days

  • All other parts: 30 days

  • No return authorization will be issued for electrical components once items are installed.

How do You Get Service?

 In order to be eligible for service under this warranty you must be the original retail purchaser, and provide 

proof of purchase from one of MAT Industries dealers, distributors, or retail outlet stores. Portable compressors or components must 

be delivered, or shipped, to the nearest Authorized MAT Industries Service Center. All associated freight costs and travel charges must 

be borne by the consumer. Please call our toll free number 1-888-895-4549 for assistance. 

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 

THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT 

THAT OF TITLE. ALL IMPLIED WARRANTIES, INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR PARTICULAR 

PURPOSE ARE HEREBY DISCLAIMED. LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES, 

OTHER CONTRACTS, NEGLIGENCE, OR OTHER TORTS IS EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. 

MAT Industries, LLC, Jackson, TN 38301 U.S.A.

Содержание C042I

Страница 1: ...AL 4 GALLON PORTABLE AIR COMPRESSOR Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontrac...

Страница 2: ...rate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors...

Страница 3: ...ower tool Do not use the tool while tired or under the influence of drugs alcohol or medication WARNING Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away...

Страница 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Страница 5: ...will not get caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use I...

Страница 6: ...grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper installation of the grounding plug may...

Страница 7: ...or industrial applications Rental applications render this warranty null and void Labor service calls and travel charges are not covered after the first year of ownership on stationary compressors com...

Страница 8: ...time 75 seconds Lubrication Oil lubricated Input 120V 60 Hz Single phase AC only 14 0 Amps Minimum branch circuit requirement 15 A Fuse type Time delay Net weight 66 lbs DUTY CYCLE This air compressor...

Страница 9: ...ed to drain condensation at the end of each use F Check Valve When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches...

Страница 10: ...flow of air Locate the air compressor as close to the main power supply as possible to avoid using long lengths of electrical wiring The air filter must be kept clear of obstructions which could reduc...

Страница 11: ...s not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury WARNING Do not attach th...

Страница 12: ...lting Inflator Brad Nailer Stapler Framing Roofing Nailer Impact Wrench Heavy Duty 1 2 in and 3 4 in Impact Wrench Air Ratchet Recommended Tool Use Tool Cutting Drilling Surface Prep Painting HVLP Pai...

Страница 13: ...essure must never exceed the maximum pressure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item...

Страница 14: ...e to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum Check the valve before each da...

Страница 15: ...injury NOTE Always use the minimum amount of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on mor...

Страница 16: ...coolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTE If the dra...

Страница 17: ...removed and cleaned Turn the air compressor OFF O Unplug the air compressor Unsnap the air filter cover 1 to remove Remove the air filter 2 from the air filter housing 3 Blow compressed air through t...

Страница 18: ...of the oil to drain Reattach the sight glass 5 Torque the sight glass 10 12 in lbs when re assembling Be sure the gasket is between the sight glass and the pump crankcase Refill the compressor pump w...

Страница 19: ...f pressure Release the air from the tank until the compressor restarts automatically The motor hums while running slowly or it does not run at all There is low voltage from the power source Call an el...

Страница 20: ...e or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is excessive water in the air tank Drain th...

Страница 21: ...21 industrialaircontractor com Please contact 1 888 895 4549 for further assistance Service Parts C042I AIR COMPRESSOR...

Страница 22: ...14 O ring Oil Fill Cap 1 2 4 15 Cover Crankcase 1 E108530 4 16 Baffle Crankcase 1 1 4 17 Assembly Piston 1 E107755 4 18 Eccentric 1 E107962 4 19 Screw SHC M8 X 1 25 X 25 mm 1 4 20 Crankcase 1 4 21 Sc...

Страница 23: ...M6 X 1 0 Nylon Insert 4 9 40 Base Air Filter 1 5 41 Element Air Filter 1 5 42 Cover Air Filter 1 5 43 Screw SHC M5 X 0 8 X 12 mm 4 44 Shroud 1 E107879 45 Tube 3 8 in Copper Outlet 1 6 46 Nut 3 8 in C...

Страница 24: ...35 E109763 5 Kit Air Filter 40 42 E100435 6 Kit 3 8 in Copper Outlet Tube 45 47 E109154 7 Kit 3 8 in Copper Pressure Relief Tube 49 51 E109155 8 Kit Pump Isolator 4 Pack 38 E109156 9 Kit Pump Mountin...

Страница 25: ...issing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com Retain this manual for future use Document Numbe...

Отзывы: