Safety Information (continued)

PERSONAL SAFETY

 

Keep proper footing and balance at all times. 
Proper footing and balance enables better control 
of the tool in unexpected situations

 

Do not use on a ladder or unstable support.

WARNING

:

 Operating any power tool can result in foreign 

objects being thrown into your eyes, which can result in 
severe eye damage. Before beginning operation, always 
wear safety goggles, safety glasses with side shields, or 
a full face shield when needed. Always use eye protection 
marked to comply with ANSI Z87.1.  

WARNING

:

 This product contains chemicals known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling. 

WARNING

:

 Use safety equipment. Always wear eye 

protection with side shields when operating power tools. 
A dusk mask, non-skid safety shoes, hard hat, or hearing 
protection must be used for appropriate conditions.

WARNING

:

 Stay alert when operating a power tool. Do 

not use the tool while tired or under the influence of drugs, 
alcohol, or medication.

WARNING

:

 Do not wear loose clothing or jewelry. 

Contain long hair. Keep your hair, clothing, and gloves away 
from moving parts. Loose clothes, jewelry, or long hair can 
be caught in moving parts.

WARNING

:

 Never touch any exposed metal parts on 

compressor during or immediately after operation. The 
compressor will remain hot for several minutes after 
operation. Do not reach around protective shrouds or 
attempt maintenance until the unit has been allowed to 
cool.

MOVING THE AIR COMPRESSOR

 

Grasp the handle.

 

When the location is reached, slowly lower the 
compressor to the ground. Always store the 
compressor in a horizontal position resting on the 
rubber bumpers.

 

When transporting the compressor in a vehicle, 
trailer, etc., make sure the tank is drained and  the 
unit is secured with straps to prevent tipping. Use 
care when driving to prevent tipping the unit over in 
the vehicle. Damage can occur to the compressor 
or surrounding items if the compressor is tipped. 
Do not lift by the shroud.

WARNING

:

 Risk of unsafe operation. Ensure proper 

footing and use caution when carrying the compressor so 
that the unit does not cause loss of balance.

Содержание C042I

Страница 1: ...AL 4 GALLON PORTABLE AIR COMPRESSOR Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontrac...

Страница 2: ...rate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors...

Страница 3: ...ower tool Do not use the tool while tired or under the influence of drugs alcohol or medication WARNING Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away...

Страница 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Страница 5: ...will not get caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use I...

Страница 6: ...grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper installation of the grounding plug may...

Страница 7: ...or industrial applications Rental applications render this warranty null and void Labor service calls and travel charges are not covered after the first year of ownership on stationary compressors com...

Страница 8: ...time 75 seconds Lubrication Oil lubricated Input 120V 60 Hz Single phase AC only 14 0 Amps Minimum branch circuit requirement 15 A Fuse type Time delay Net weight 66 lbs DUTY CYCLE This air compressor...

Страница 9: ...ed to drain condensation at the end of each use F Check Valve When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches...

Страница 10: ...flow of air Locate the air compressor as close to the main power supply as possible to avoid using long lengths of electrical wiring The air filter must be kept clear of obstructions which could reduc...

Страница 11: ...s not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury WARNING Do not attach th...

Страница 12: ...lting Inflator Brad Nailer Stapler Framing Roofing Nailer Impact Wrench Heavy Duty 1 2 in and 3 4 in Impact Wrench Air Ratchet Recommended Tool Use Tool Cutting Drilling Surface Prep Painting HVLP Pai...

Страница 13: ...essure must never exceed the maximum pressure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item...

Страница 14: ...e to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum Check the valve before each da...

Страница 15: ...injury NOTE Always use the minimum amount of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on mor...

Страница 16: ...coolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTE If the dra...

Страница 17: ...removed and cleaned Turn the air compressor OFF O Unplug the air compressor Unsnap the air filter cover 1 to remove Remove the air filter 2 from the air filter housing 3 Blow compressed air through t...

Страница 18: ...of the oil to drain Reattach the sight glass 5 Torque the sight glass 10 12 in lbs when re assembling Be sure the gasket is between the sight glass and the pump crankcase Refill the compressor pump w...

Страница 19: ...f pressure Release the air from the tank until the compressor restarts automatically The motor hums while running slowly or it does not run at all There is low voltage from the power source Call an el...

Страница 20: ...e or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is excessive water in the air tank Drain th...

Страница 21: ...21 industrialaircontractor com Please contact 1 888 895 4549 for further assistance Service Parts C042I AIR COMPRESSOR...

Страница 22: ...14 O ring Oil Fill Cap 1 2 4 15 Cover Crankcase 1 E108530 4 16 Baffle Crankcase 1 1 4 17 Assembly Piston 1 E107755 4 18 Eccentric 1 E107962 4 19 Screw SHC M8 X 1 25 X 25 mm 1 4 20 Crankcase 1 4 21 Sc...

Страница 23: ...M6 X 1 0 Nylon Insert 4 9 40 Base Air Filter 1 5 41 Element Air Filter 1 5 42 Cover Air Filter 1 5 43 Screw SHC M5 X 0 8 X 12 mm 4 44 Shroud 1 E107879 45 Tube 3 8 in Copper Outlet 1 6 46 Nut 3 8 in C...

Страница 24: ...35 E109763 5 Kit Air Filter 40 42 E100435 6 Kit 3 8 in Copper Outlet Tube 45 47 E109154 7 Kit 3 8 in Copper Pressure Relief Tube 49 51 E109155 8 Kit Pump Isolator 4 Pack 38 E109156 9 Kit Pump Mountin...

Страница 25: ...issing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com Retain this manual for future use Document Numbe...

Отзывы: