34
INSTINCT Griddle User Manual rev 01 04/18
Troubleshooting
Section 5
Tr
oublesho
oting
W
ithout Err
or C
ode
Sympt
om
Possible C
ause
A
ction
Gr
iddle not hea
ting up
.
Dig
ital displa
y is OFF (dar
k).
No po
w
er supply
.
Check inc
oming po
w
er supply (Example
, po
w
er cable plugged
in
to the w
all socket). Check k
itchen main fuse bo
x.
Unit is tur
ned off
.
Tur
n c
on
tr
ol k
nob t
o an ON-position.
D
ef
ec
tiv
e equipmen
t
Only if possible and saf
e, disc
onnec
t the applianc
e fr
om the
po
w
er supply
. (1)
Con
tac
t an author
iz
ed ser
vic
e agenc
y.
Gr
iddle not hea
ting up
.
“S
er
vic
e”
symbol is ON.
D
ef
ec
tiv
e Unit
Only if possible and saf
e, disc
onnec
t the applianc
e fr
om the
po
w
er supply
. (1) C
on
tac
t an author
iz
ed ser
vic
e agenc
y.
Poor hea
ting
, LED r
ing is ON
A
ir-
cooling sy
st
em is
obstruc
ted
.
Ver
ify tha
t air v
en
ts ar
e not obstruc
ted
. Ensur
e the fr
esh air filt
er is
clean.
A
mbien
t t
emper
atur
e is t
oo
high.
The c
ooling sy
st
em is not
able t
o keep the applianc
e in
nor
mal oper
ating c
onditions
.
Ver
ify tha
t no hot air is taken in b
y the fan. R
educ
e the ambien
t
temper
atur
e.
The in
take air t
emper
atur
e must be lo
w
er than 40°C
[104°F].
One phase is missing (f
or
equipmen
t with thr
ee phase
supply only).
Check inc
oming po
w
er supply (Example
, po
w
er cable plugged
in
to the w
all socket). Check k
itchen main fuse bo
x.
Reduc
ed P
ow
er adj
.
Check if the additional S
etting
“P1”
is c
or
rec
t.
D
ef
ec
tiv
e equipmen
t
Only if possible and saf
e, disc
onnec
t the applianc
e fr
om the
po
w
er supply
. (1)
Con
tac
t an author
iz
ed ser
vic
e agenc
y.
A
pplianc
e does not r
eac
t t
o
con
tr
ol k
nob positions
D
ef
ec
tiv
e c
on
tr
ol k
nob
.
Only if possible and saf
e, disc
onnec
t the applianc
e fr
om the
po
w
er supply
. (1)
Con
tac
t an author
iz
ed ser
vic
e agenc
y.
O
ver
hea
ted unit symbol is
ON, fan is w
or
king
A
ir-
cooling sy
st
em is
obstruc
ted
. I
nt
er
nal fan is dir
ty
.
Ver
ify tha
t air v
en
ts ar
e not obstruc
ted
. Ensur
e the fr
esh air filt
er is
clean. Con
tac
t an author
iz
ed ser
vic
e agenc
y.
O
ver
hea
ted unit symbol is
ON, fan does not w
or
k
D
ef
ec
tiv
e fan or fan c
on
tr
ol
.
Only if possible and saf
e, disc
onnec
t the applianc
e fr
om the
po
w
er supply
. (1)
Con
tac
t an author
iz
ed ser
vic
e agenc
y.
O
ver
hea
ted unit symbol is ON
O
ver
hea
ted induc
tion c
oil;
cook
ing ar
ea is t
oo hot
.
Swit
ch the applianc
e off
. W
ait un
til the applianc
e has c
ooled
do
wn bef
or
e tur
ning it ON again.
(1)
n
D
ANGER
If the plug is not saf
ely ac
cessible
, the devic
e must be swit
ched off a
t the main cir
cuit br
eaker
.
Содержание INSTINCT Griddle 10
Страница 7: ...INSTINCT Griddle User Manual rev 01 04 18 7 Safety Notices ...
Страница 37: ...INSTINCT Griddle User Manual rev 01 04 18 37 Section 5 Troubleshooting ...
Страница 38: ...38 INSTINCT Griddle User Manual rev 01 04 18 Troubleshooting Section 5 ...
Страница 39: ...INSTINCT Griddle User Manual rev 01 04 18 39 Section 5 Troubleshooting ...