MICROCOM
®
TEMPERATURE CONTROLLER
INSTRUCTION MANUAL
Pg.
www.incoe.com
©INCOE
®
CORPORATION 4/2010
2.5 CONTROLLER OPERATING MODE:
2.5.1 DESCRIPTION:
This controller consists of the following:
A “CLICK & ROTATE” switch for data entry
and viewing.
2 sets of 3 digits displays (7 se DP),
the upper display is red (it is used for displaying
temperatures, alarms and screen parameters), the
lower display is green (it is used for displaying
the temperature setpoint and the various other
parameter values).
3 LED signals :
#1 : Auto/Manual, when lit controller is in
Manual mode.
#2 : heating rate indicator (percentage of
power display).
#3 : SoftStart Mode.
Upper digits
Lower digits
2.5.2 STANDBY DISPLAY:
In normal operating mode, the upper digits display
the temperature whereas the lower ones display
the setpoint.
If an alarm or a fault, occurs it will be displayed on
the upper digits.
The “On / Off” and “Increase / Decrease”
functions are the only ones operational in the
standby screen display.
The 3 indicators (LED) will only be displayed on the
upper display .
2.5.3 “CLICK & ROTATE” SWITCH
OPERATING MODE:
A single switch is used for performing various
tasks, This switch possesses several functions as
outlined below.:
• 3 second button push = Switches the
controller ON / OFF.
• 5 second button push to unlock if in Lock mode.
• A Double-click allows entry to or to exit
from menu.
i.e. From Stand-By display : a double click
enters in to Main menu, and another double
click exits the Main menu.
• 2 second button push = allows the selection
of a parameter (Parameter is blinking) and the
modification of it.
• If a parameter has been modified, another 2
second push is required to save value.
• Increase / Decrease (Turn right or left) = modify
the parameters and to navigate through the
different menus.
• The standby display becomes active again if
the “Click & Rotate” switch remains untouched
for 5 seconds.
#1
#2
#3
2
OPERATION
5