MICROCOM
®
TEMPERATURE CONTROLLER
INSTRUCTION MANUAL
©INCOE
®
CORPORATION 4/2010
Pg.
www.incoe.com
• The controller type (World).
• The thermocouple type and
the temperature unit
(F or C) used.
• The plant facility’s power
supply frequency and the
detection of the anti-arcing
function (anti-arcing system
detected, anti-arcing system
undetected not detected).
• The version of the
installed software.
• To Switch on the controller (keep the rotary
knob pressed for 3 seconds).
• If the controller displays , this
means either the thermocouple is broken
or is incorrectly wired. In this case, the
controller does not apply any voltage to the
heater (Except if “otc” parameter is set at
“ON”). The problem needs to be corrected
before continuing.
• If the controller displays , it means
the thermocouple is reversed. In this case, the
controller does not apply any voltage to the
heater. The problem needs to be corrected
before continuing.
• If temperature when starting is below 212°F or
100°C, the SoftStart is activated.
In case of problems during start up, refer to the
chapter “Instructions for maintenance”.
2.1 REQUIREMENTS FOR INSTALLING
AND USING:
The control module is designed to operate in a dry
industrial environment.
Operating Temperature range : from 14°F to +158°
or -10°C to +70°C.
2.2 SAFETY REQUIREMENTS:
The controller is protected by :
• Fuses protect TRIAC against over current draw.
• Overvoltage safety feature for protection of
the controller if in put voltage supply
exceeds 275 V.
• Safety relay designed for protection of the
heating element.
2.3 INSTRUCTIONS FOR INSTALLATION:
The controller can be installed in industry standard
enclosures or cabinets. Before installing the
control module make certain the module will fit
into the cabinet. If there are any questions please
contact INCOE
®
.
2.4 INITIAL START UP
• Install the controller(s) in the appropriate
enclosure or cabinet.
• Connect the cabinet’s power input cable to the
facilities power supply.
• Check all wiring to and from the cabinet.
• Once connected to the plant power supply,
turn on the cabinet using the circuit breaker
on the cabinet.
• At start-up , the display will indicate its status
by the display shown here:
2
OPERATION
4