2.5.4 “CLICK & ROTATE” SWITCH
LOCKING PROCEDURE:
If the LOC parameter is set to ON (in the
configuration 2 menu), the switch is then
automatically locked after 30 seconds if inactive.
To temporarily unlock the switch, depress the
knob for 5 seconds.
If the button is locked and depressed, then a
“LOC” message will be displayed.
2.5.5 ALARM DESCRIPTIONS:
Alarms and faults only show in the standby
Display, either in a fixed or blinking manner with
the temperature value, as outlined below:
Open thermocouple fault:
• Continuous display of this
fault in the standby display.
Reversed thermocouple fault:
• Continuous display of this
fault in the standby display.
Disconnected heating element fault:
• This fault displays alternately
with temperature. An open
heater is automatically
detected by current
measurement. If the measured
current is 0 and if the
percentage of power is greater
than 0, then this is detected as
a load (heater) fault.
Shorted TRIAC fault:
• This fault displays alternately
with temperature. A shorted
TRIAC is automatically
detected if the measured
current differs from 0 and if
the percentage of power =0.
Heating element load resistance fault:
• This fault displays alternately with
temperature. Automatic detection
of load nominal power variation.
after a 120 second stabilization
period of the temperature
control (tempe/- 3 °F / °C
of setpoint), the system keeps
the nominal power in memory
and activates an alarm if there
is a variation of at least –20% with
respect to this nominal power.
Temperature high alarm:
• This fault displays alternately
with temperature. It displays
when temperature is higher
than the se parameter
High alarm value, adjustable in
configuration 1.
Temperature low alarm:
• This fault displays alternately
with temperature. It displays
when temperature is less than
the setpoint parameters Low
alarm value, adjustable in
configuration 1.
2.5.6 OPERATOR INTERFACE MENU:
General View of Menu organization.
Main Menu (Double Click to enter or Exit).
Control mode selection
Display Percentage of
applied power
Display Installed heater power
Display Current measurement
Configuration menu selection
(Push 2 seconds to modify,
Rotate to select 1 or 2, Push 2
seconds again to confirm).
Rotate
2
OPERATION
6