USER MANUAL
PAGE 08
PAGE 09
IMPORTANT!
You must observe the ventilation requirements shown in the drawing below.
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
IMPORTANT!
Do not use a silicon sealant to seal the appliance against the aperture. This will make it difficult
to remove the cooktop from the aperture in the future, particularly if it needs to be serviced.
► Carefully lower the cooktop into the cut-out.
ELECTRICAL CONNECTION
IMPORTANT!
The connection of this cooktop must be carried out by a suitably qualified and licensed electrician,
in accordance with the current versions of the following:
► Gas Safety and Measurement Regulations 2010
► AS/NZS 3000 Wiring Rules
► Electricity Safety Regulations 2010
► The installation instructions within this user manual
IMPORTANT!
The safety distance between the hotplate and the cupboard above the hotplate should be
at least
700mm.
There must be a gap of at least 35 mm between the underneath of the appliance and this partition.
Ensure the appliance is well ventilated and the air intake channel should be at least mm.
20
CONNECTING THE MAINS SUPPLY CABLE
► The mains terminal block is located on the underside of the cooktop and the terminals are accessible by removing the
terminal block cover.
IMPORTANT!
The power cable isn’t supplied with the appliance. The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
► The cable connections must be in accordance with the diagram located on the bottom of the cooktop. The links must
also be positioned as indicated.
► You should use a good quality screwdriver to carefully, fully tighten ALL of the terminal screws.
► If when the cooktop is first switched on, only two of the zones work, you should recheck that the terminal screws are
all fully tightened and the links are in position. This should be done before contacting the Customer Care Department.
► The cable can be looped if necessary, but make sure that is not kinked or trapped when the cooktop is in position.
Care
must be taken to avoid the cable being in contact with hot parts of the appliance.
REPLACING THE MAINS SUPPLY CABLE
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement which can be obtained
via the manufacturer or its service agents, in order to avoid hazard.
IMPORTANT!
The replacement of the mains supply cable must be carried out by a suitably qualified and
licensed electrician.
The mains supply cable should be replaced in accordance with the following instructions:
► Switch the appliance off at the mains supply.
► Open the terminal block on the underside of the cooktop.
► Unscrew the terminal screws fixing the cable.
► Replace the cable with one of the same length and in accordance with the specification given on pages 17 - 18.
► The “green-yellow” earth wire must be connected to the terminal marked . It must be about 10 mm longer than the
live and neutral wires.
► The “blue” neutral wire must be connected to the terminal marked with letter (N) - the live wire must be connected to
the terminal marked with letter (L).
► The appliance must be wired into a 32A double pole switched fused spur outlet, having 3mm contact separation and
placed in an easily accessible position adjacent to the appliance. It should not be located above the appliance and no
more that 1.25m away from it.
► The spur outlet must still be accessible even when your cooktop is located in its operating position.
► Cable type: H05BB-F5G 1.5mm2, HO5BQ-F5G 1.5mm2, H05V2V2-F5G 1.5mm2
Before connecting the cooktop, make sure that the supply voltage marked on the rating plate corresponds with that of
your mains supply voltage.
Warning!
The cooktop must be earthed.