14
Welding spot counter
The spot counter will count the number of spot welds performed with the same caps. If the welding spot is performed
without any problem, the message below left, appears. The counter is displayed on the top left corner of the screen. After
the caps have been replaced, press the button
to reset the counter to zero
.
If more than 200 welding spots are done with the same caps, then the machine will display the below warning message. In
this case, the warning message “Change tips” is also recorded in the traceability report..
Attention: After the warning message is displayed, if the caps are not changed before resetting the counter
to zero, the caps may become badly damaged and cause poor quality welding.
Recording features
The "Identification" mode is optional; you can configure it in the settings menu which is activated by pushing the mode
button for 2 seconds (identification mode on/off). If the identification mode is « off », enter a file name and activate it to
store the information of the welding spots made in the memory. The log book stores the spots made with the clamp in the
memory. It is available in all modes by pressing both buttons located bellow the “reporting” icon.
The user’s program is available in all modes by pushing the buttons bellow the “memory” icon.
Report (log book)
The new report has: an identifier entered by the user, all the spots made, the arm and the clamp used, the settings (voltage
and pressure). It puts also stores any messages received whilst recording: LOW I, LOW P, CAPS PB. You can enter the
identifier using the 4 buttons: +, -, up or down. If you enter an identifier that has already been used, the unit will save the
new spot information, without erasing the old ones.
The View button
allows the user to retrieve a previously saved report and view it on the screen.
To view a report, stop any current recording by pressing
. Use the « mode » button to exit the report displayed.
Saving a report allows spot welding data to be stored on a memory
card, in order to retrieve it at a later date e.g. on a computer.
JBDC supplies software called SPOT to read the SD card and the user
manual.
By default, the report mode is not activated when the machine is
started.
Pressing the record button (on/off)
and the « mode » button
starts the recording process in the selected log file. To stop saving the
information, press the save button again.