![IMS MDrive 34 Plus Series Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/ims/mdrive-34-plus-series/mdrive-34-plus-series_hardware-reference-manual_2049848038.webp)
2-14
MDrive34Plus Motion Control Hardware Revision R080106
Active LOW example:
IO 1 is to be configured as a Jog– input which will activate when a switch is toggled to ground (Sinking
Input):
S1=8,0,0
‘set IO point 1 to Jog–, Active LOW, Sinking
Active HIGH example:
IO 4 is to be configured as a Home input which will activate when instructed by a PLC (+24VDC Sourc-
ing Input):
S4=1,1,1
‘set IO point 1 to Home, Active HIGH, Sourcing
MDrivePlus Motion Control Digital Output Functions
The MDrivePlus Motion Control Outputs may be configured as general purpose or set to one of two dedi-
cated functions, Fault or Moving. These outputs will sink up to 600 mA (one channel of two banks) and may
be connected to an external VDC source. See Output Functions Table and I/O Ratings Table.
The outputs are set using the “S” comand (See MDrive Motion Control Sofware Reference Manual for
precise details on this command). The command is entered into the IMS terminal or program file as S<IO
point>=<IO Type>,<Active State><Sink/Source>.
Example:
S9=17,1,0
‘set IO point 9 to be a Moving Output, Active HIGH, Sinking
S3=18,0,0
‘set IO Point 3 to be a Fault Output, Active LOW, Sinking
Programmable Output Functions
The MDrivePlus Motion Control Output functions may be programmed to be a general purpose user output
or to one of five output functions.
MDrivePlus Motion Control Output Functions
Parameter
(S1-S4, S9-S12)
Function
Active
Sink/Source
16
General Purpose User
0/1
0/1
17
Moving
0/1
0/1
18
Fault
0/1
0/1
19
Stall
0/1
0/1
20
Velocity Changing
0/1
0/1
Table 2.3.3: Programmable Output Functions
Dedicated Output Functions
MDrivePlus Motion Control Dedicated Output Functions
Parameter
(S7, S8)
Function
Active
49
Step/Direction
0/1
50
Quadrature
0/1
51
Up/Down
0/1
Parameter
(S13)
Function
Active
61
High Speed Trip
0/1
Table 2.3.4: Dedicated Output Functions
NOTE: On
the Standard
MDrivePlus, when
configured as outputs, the
I/O set is sinking ONLY!
The Plus2 Models add the
functionality of I/O Power,
which enables the user to use
all the outputs, both Standard
and Enhanced, as Sinking or
Sourcing.
Содержание MDrive 34 Plus Series
Страница 12: ...1 6 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 24: ...1 18 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 26: ...2 2 MDrive34Plus Motion Control Hardware Revision R080106 ...
Страница 50: ...2 26 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 52: ...A 2 MDrive34Plus Motion Control Hardware Manual Revision R080106 Page Intentionally Left Blank ...
Страница 66: ...A 16 MDrive34Plus Motion Control Hardware Manual Revision R080106 Page Intentionally Left Blank ...