![IMS MDrive 34 Plus Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/ims/mdrive-34-plus-series/mdrive-34-plus-series_hardware-reference-manual_2049848037.webp)
2-13
Part 2: Connections and Interface
Motion Control.
Each I/O point may be individually programmed to any one of 9 dedicated input functions, 4 dedicated output functions, or
as general purpose inputs or outputs. The I/O may be addressed individually, or as a group. The active state of the line or group
may also be set. All of these possible functions are accomplished with the I/O Setup Variable (S1-4, S9-12)
When the level is HIGH. The active HIGH/LOW state is configured by the second parameter of the I/O Setup (S1-4, S9-12)
variable. The goal of this I/O configuration scheme is to maximize compatibility between the MDrivePlus Motion Control and
standard sensors and switches.
MDrivePlus Motion Control Digital Input Functions
The MDrivePlus Motion Control inputs may be interfaced to a variety of sinking or sourcing devices. An input may be pro-
grammed to be a general purpose user input, or to one of nine dedicated input functions. These may then be programmed to
have an active state of either HIGH or LOW.
The inputs are configured using the “S” Variable (See MDrive Motion Control Sofware Reference Manual for precise de-
tails on this command). The command is entered into the IMS terminal or program file as S<IO point>=<IO Type>,<Active
State><Sink/Source>.
Example:
S9=3,1,0
‘set IO point 9 to be a Limit- input, Active HIGH, Sourcing
S3=0,0,1
‘set IO Point 3 to be a General Purpose input, Active LOW,
‘Sinking
Programmable Input Functions
The following table lists the programmable input functions of the MDrive Motion Control.
MDrivePlus Motion Control Input Functions
Parameter
(S1-S4, S9-S12)
Function
Active
Sink/Source
0
General Purpose
0/1
0/1
1
Home
0/1
0/1
2
Limit +
0/1
0/1
3
Limit –
0/1
0/1
4
GO
0/1
0/1
5
Soft Stop
0/1
0/1
6
Pause
0/1
0/1
7
Jog +
0/1
0/1
8
Jog –
0/1
0/1
11
Reset
0/1
0/1
Table 2.3.1: Programmable Input Functions
Dedicated Input Functions
MDrivePlus Motion Control Dedicated Input Functions
Parameter
(S7, S8)
Function
Active
33
Step/Direction
0/1
34
Quadrature
0/1
35
Up/Down
0/1
Parameter
(S13)
Function
Active
60
High Speed Capture
0/1
Table 2.3.2: Dedicated Input Functions
Active States Defined
The Active State determines at what voltage level the input will be active.
Active HIGH ...................................................................... The input will be active when +5 top +24 VDC is applied to
the input.
Active LOW ........................................................................ The input will be active when it is gorunded (0 VDC).
Содержание MDrive 34 Plus Series
Страница 12: ...1 6 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 24: ...1 18 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 26: ...2 2 MDrive34Plus Motion Control Hardware Revision R080106 ...
Страница 50: ...2 26 MDrive34Plus Motion Control Hardware Revision R080106 Page Intentionally Left Blank ...
Страница 52: ...A 2 MDrive34Plus Motion Control Hardware Manual Revision R080106 Page Intentionally Left Blank ...
Страница 66: ...A 16 MDrive34Plus Motion Control Hardware Manual Revision R080106 Page Intentionally Left Blank ...
Страница 82: ...A 32 MDrive34Plus Motion Control Hardware Manual Revision R080106 Page Intentionally Left Blank ...