IMS GOLD MULTI 140
Translation of the original instructions
EN
21
SYMPTOMS
POSSIBLE CAUSES
REMEDIES
The welding bead is
porous
The gas flow rate is not sufficient.
Adjust flow range 15 to 20 L / min.
Clean the working metal.
Gas bottle empty.
Replace it.
Gas quality unsatisfactory.
Replace it.
Air flow or wind influence.
Prevent drafts, protect welding area.
Gas nozzle dirty.
Clean or replace the gas nozzle.
Poor quality wire.
Use suitable WIRE for MIG-MAG welding.
Surface to weld in bad condtion. (rust,
etc…)
Clean the metal before welding.
Very important flashing
particules.
Arc voltage too low or too high.
See welding settings.
Bad earth connection.
Adjust the earth cable for a better connec-
tion.
Insufficient gas flow.
Adjust the gas flow.
No gas flow at the end of
the torch.
Bad gas connection.
Check the gas connection at the welding
machine. Check the gas regulator and the
solenoid valves.