IMS GOLD MULTI 140
Translation of the original instructions
EN
16
TRANSPORT AND TRANSIT OF THE MACHINE
The machine is equipped with handles. Be careful not to underestimate the machine’s weight.
Do not use the cables or torches to move the machine. It must be moved in a vertical position.
Transportation standards are different.
Never lift the machine on top of persons or objects.
INSTALLATION
These machines can work in difficult environments. However it is essential to follow the instructions listed below :
• Put the machine on a floor with a maximum inclination of 10°.
• Provide adequate space for the machine’s ventilation and easy access to the controls.
• The machine must be protected form the heavy rain and the sun’s rays .
• The machine must not be used in an area with metal dusts.
The manufacturer does not accept responsilbity for damage resulting from incorrect and/or
dangerous use of the machine .
MAINTENANCE / RECOMMENDATIONS
Unplug the power source before any maintenance operation.
All operations requiring the removal of the power source’s cover must be done by a qualified
technician.
1 - Periodical maintenance:
• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections
checked by a qualified person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced
by the manufacturer, an after sales service or a qualified person to prevent danger.
• Do not obstruct the machine’s air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn .
INSTALLATION – PRODUCT OPERATION
DESCRIPTION
Thank you for chosing this machine. To get the best use from your machine, please read the following carefully :
The GOLD MULTI range are semi-automatic MIG/MAG, MMA and flux cored wire welding stations. They are
manual settings machine, with the help of the table printed on the product. They are recommended for welding
steel, stainless steel and aluminium.
ELECTRICITY SUPPLY
The absorbed current (I1eff) is indicated on the device at maximum usage. Check that the power supply and
its protection (fuse and/or circuit breaker) are compatible with the current needed for use. In some countries, it
might be necessary to change the plug to allow maximum performance. The device must be installed so that the
mains socket is accessible.