background image

11

Parity: none

Stop bit: 1

Flow control: none.

An example of transmission is shown here below: 

Pocket ultrasonic tester – Ver Version 00.01.001 
------------------------------ 
N. Date     Time     S Measure
0000 07/10/10 16:03.00 X 0055.0
0001 07/10/10 16:03.00 X 0050.6
0002 07/10/10 16:03.00 X 0050.7
0003 07/10/10 16:03.00 X 0050.7
0004 07/10/10 16:04.00 Y 0055.4
0005 07/10/10 16:04.00 Y 0055.3
0006 07/10/10 16:05.00 Y ----.-
0007 07/10/10 16:05.00 Y 0050.6
0008 12/10/10 10:34.00 A 0004.8
0009 12/10/10 10:34.00 A 0004.6
0010 12/10/10 11:29.00 C 0000.0
#####

The list of measures is more complete than the one that is displayed on the appliance because, in addition to 
the  previously  mentioned  values,  it  shows  also  when  (the  time)  the  measures  have  been  taken.  Moreover, 
the measures with negative results are also listed. 

After the transmission, the data are not deleted from the tester and, therefore, they remain at disposal for 
further uses. However, they can be manually deleted through the proper menu. 
To avoid interferences with the results, it is advisable to keep the mini USB cable always disconnected from 
the tester during the measuring phase.  

2.09  CONNECTIONS 

The tester is provided with two sets of outwards connections. In the upper part there are: 

Mini USB connector: for the communication with the host PC and for the data download;

6 mm circular connector: for the connection with the battery charger provided with the equipment.

In the lower part there are the signal connectors: 

TX:  terminal for the connection of the transmitting probe;

RX:  terminal for the connection of the receiving probe;

Trigger: synchronization signal for the oscilloscope visualization

••••

Scope: analog signal visualization received by the tester.

N.B. 

PLEASE  DO  NOT  CONNECT  THE  TERMINAL  TX  WITH  RX  USING  THE  CABLES  OF  THE 
PROBES

In  order  to  recharge  the  batteries,  always  and  only  use  the  battery  charger

provided  with  the  kit.  In  case  of  fault  or  malfunction,  contact  the
manufacturer/reseller to change the battery charger itself.

Never  connect  the  battery  charger  to  the  appliance  if  the  batteries  are  not

www.impact-test.co.uk     

      www.impact-test.com      

 www.impact-testsets.co.uk 

Содержание CN842

Страница 1: ...User Guide User Guide www impact test com www impact test co uk www impact testsets co uk Ultrasonic Pulse Velocity Tester CN842 Impact Test Equipment Ltd www impact test co uk www impact test com www impact testsets co uk ...

Страница 2: ...est Equipment Ltd Building 21 Stevenston Ind Est Stevenston Ayrshire KA20 3LR T 01294 602626 F 01294 461168 E sales impact test co uk Test Equipment www impact test co uk Test Sieves Accessories www impact test com Test Sets to International Standards www impact testsets co uk ...

Страница 3: ...www impact test co uk www impact test com www impact testsets co uk 1 ...

Страница 4: ...ice are however present Such risks can be reduced by carefully following manual procedures using the suggested individual protection devices and respecting the legal and safety norms in force This manual includes Warning and Danger indications in relevant chapters These indications are shown with the words Danger or Warning in bold font and uppercase to make them highly visible WARNING indicates t...

Страница 5: ...re of the Instructions Manual 1 05 Composition of the Instructions Manual 1 06 Modifications and enclosures of the Instructions Manual 1 07 Constructor Identification 1 08 Machine Identification Data 1 09 EC Stamp 1 10 Usage 1 11 Operators 1 12 Storage 1 13 Transportation and Movement 1 14 Packaging removal Chapter 2 INSTRUCTIONS FOR USE 2 01 Main features 2 02 Case contents 2 03 Operator interfac...

Страница 6: ...conditions of danger immediately stop the machine should it be working irregularly and consult the authorised dealer s Sales Service department It is the Client s responsibility to verify at the time of installation and use that no conditions of use arise which are different to those indicated Refer to the Constructor when in doubt 1 11 OPERATORS WARNING DANGER The use transportation installation ...

Страница 7: ...ity of 70 WARNING The tester as almost all electronic appliances must not be put in too cold or humid environments when not used otherwise it could not work properly Therefore before its use it is recommended that the appliance is kept in environments with a low level of humidity and a minimum temperature of 20 1 13 TRANSPORTATION AND MOVEMENT WARNING In order to avoid irreparable machine damage m...

Страница 8: ...ime If the instruction above is not respected the batteries pack will be damaged quickly WARNING UNUSED OF THE EQUIPMENT if the equipment is not used for more than 15 days the information and memorization of the date and time will be lost At the first re start the operator has to set the correct date and time 2 02 CASE CONTENTS 2 ultrasonic probes 2 cables for probes 3 5m each 42 5µs sample contac...

Страница 9: ... of the tester are shown on a 128x64 pixel LCD display FUNCTIONS KEYBOARD 2 04 MAIN SCREEN By switching the appliance on the main screen becomes active and the operator can use the following functions in top down order Start of the acquisition Display of the configuration menu Display of the saved measures Download of the data through the mini USB port of the tester The main screen will be as the ...

Страница 10: ...quisition CONTINUOUS MODE The acquisition takes place in a mediated mode four measures are taken within a second checking that they fall within the range of the tester and that they are consistent with each other Otherwise the NOT VALID notice appears The operation is repeated three times checking the data consistency again Only in this case if the automatic save function is active data are saved ...

Страница 11: ... the main screen 2 06 CALIBRATION By selecting the appropriate entry of the configuration menu and by pressing the F2 key it is possible to perform a two points calibration in order to achieve the highest possible level of precision on the performed measures By starting the calibration the following screen appears START CALIBRATION EXIT This screen suggests the operator should bring the probes in ...

Страница 12: ... of the measure under consideration some values can be missing because of the deletion of one or more measures Tests identification in order to make the continuous mode tests more evident every single test is identified by a character which is gradually increased at the starting of any new test Time to fly it represents the elapsed time between the ultrasonic signal emission in the TX channel and ...

Страница 13: ...u To avoid interferences with the results it is advisable to keep the mini USB cable always disconnected from the tester during the measuring phase 2 09 CONNECTIONS The tester is provided with two sets of outwards connections In the upper part there are Mini USB connector for the communication with the host PC and for the data download 6 mm circular connector for the connection with the battery ch...

Страница 14: ...order to preserve the machine and its efficiency Avoid the use of solvents which damage paint and parts in synthetic material 3 03 AUTHORISED MAINTENANCE CENTRES For information on the nearest authorised help centre it is essential to contact the manufacturer Chapter 4 SPARE PARTS Accessories C370 08 Exponential couple of transmitting and receiving PROBES nominal frequency 55kHz C372 10 Couple of ...

Страница 15: ...ble Make the potential sources of danger harmless such as sharp or protruding parts Dismantle the machine divide it into similar parts and dispose of according to the standards in force Recycling notice for the disposal of electrical and electronical devices This symbol shown on the device or on the package and or the documentation suggests that the device should not be disposed together with othe...

Отзывы: