19
STZSkW ed 12/07
ZEUS Superior kW
Technical Documentation
Technical Documentation
Ø 80/80 push-fit twin pipe flue kit.
Both pipes have an 80 mm diameter.
Boiler connections are obtained by means of two flanges,
discharging flue (4) through the central fitting and taking air
in (3) from one of the two side holes.
The maximum allowed length
(air + flue)
is 33 straight hori-
zontal meters and 41 straight vertical meters.
In order to avoid condensate problems, flue duct length is to
be
limited to 5 meters.
Ø 80/80 push-fit insulated twin pipe flue kit.
The functional diameter is 80 mm for both pipes.
Boiler connections are obtained by means of two flanges,
discharging flue (4) through the central fitting and taking air
in (3) from one of the two side holes.
Tightness is ensured by special gaskets (6); they create an air
space with the external Ø 125 mm concentric pipe.
Maximum allowed length
is 33 straight meters
(air + flue).
In order to avoid problems with condensate, flue duct length
is to be
limited to 12 meters.
Ø 80/125 push-fit vertical concentric kit.
The flue duct (Ø 80 mm) is inserted in the intake duct (Ø
125 mm).
Connect to the boiler using a flange (2). Using the
60/100-80/125 adapter (3) and the appropriate extensions,
connect to the 80/125 air and flue terminal with an aluminum
tile (6).
Maximum allowed length is
12.2 straight vertical me ters.
Ø 60/100 push-fit vertical terminal kit.
The flue duct (Ø 60 mm) is inserted directly in the intake
duct (Ø 100 mm).
Connect to the boiler using a flange (2). Using the appropriate
extensions, connect to the 60/100 air and flue terminal with an
aluminum tile. The maximum length allowed is
4.7 straight
vertical meters.
6
2
1
3
4
5
7
8
5
7
6
1
3
2
8
9
6
10
8
4
A
B
5
4
1
3
2
6
7
8
9
9
11
12
5
10
A
B