3.25 TECHNICAL DATA.
- Flue temperature values refer to an air inlet
temperature of 15°C and flow temperature of
50°C.
- The maximum sound level emitted during
boiler operation is < 55dBA. The sound level
value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
Victrix PRO 35 1I
Victrix PRO 55 1I
Nominal heat input
kW (kcal/h)
34.9 (30051)
51.3 (44098)
Minimum heat input
kW (kcal/h)
3.9 (3388)
5.5 (4715)
Nominal heat output (useful)
kW (kcal/h)
34.0 (29240)
49.9 (42914)
Minimum heat output (useful)
kW (kcal/h)
3.4 (2924)
5.0 (4300)
Efficiency 80/60 Nom./Min.
%
97.3 / 86.3
97.3 / 91.2
Efficiency 50/30 Nom./Min.
%
107.0 / 94.7
106.8 / 99.7
Efficiency 40/30 Nom./Min.
%
107.3 / 100.2
107.4 / 103.5
Heat loss at casing with burner On/Off (80-60°C)
%
0.44 / 1.10
0.30 / 0.90
Heat loss at flue with burner On/Off (80-60°C)
%
0.04 / 1.60
0.03 / 1.80
Central heating circuit max. operating pressure
bar
4.4
4.4
Central heating circuit max. operating temperature
°C
90
90
Adjustable central heating temperature
°C
20 - 85
20 - 85
Head available with 1000 l/h flow rate
kPa (m H
2
O)
46.30 (4.72)
46.30 (4.72)
Weight of full boiler
kg
54.0
54.2
Weight of empty boiler
kg
51.2
51.4
Boiler water content
l
2.8
2.8
Electrical connection
V/Hz
230/50
230/50
Nominal absorption
A
0.90
1.0
Installed electric output
W
140
195
Pump consumption
W
98
98
Fan power consumption
W
28
73
Equipment electrical system protection
-
IPX5D
IPX5D
Functioning room max. temperature
°C
+50
+50
Functioning room min. temperature
°C
-5
-5
Functioning room min. temperature with anti-freeze kit (Optional)
°C
-15
-15
Flue gas max. temperature
°C
75
75
NO
X
class
-
5
5
Weighted NO
X
mg/kWh
25
39
Weighted CO
mg/kWh
8
15
Type of appliance
C13 / C33 / C63 / B23p / B33 / B53p
Category
II2H3 P