34
INS
TALLER
U
SER
M
AINTEN
AN
CE
TECHNI
CI
AN
TECHNI
CAL
D
AT
A
Mounting the vertical kit with aluminium tile Ø 80/125 (Fig. 24)
To install the kit Ø 80/125 one must use the flanged adapter kit in order to install the flue system Ø 80/125.
1. Install the concentric flange (2) on the central hole of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange.
2. Tighten the concentric flange with the screws in the kit.
3. Replace the tiles with the aluminium sheet (4), shaping it to ensure that rainwater runs off.
4. Position the fixed half-shell (5) on the aluminium tile;
5. Insert the intake-exhaust terminal (7);
6. Fit the Ø 80/125 concentric terminal pipe with the male side (smooth) to the female side of the adapter (1) (with lip seals) up to the end
stop, making sure that the wall sealing plate (3) has been fitted; this will ensure sealing and joining of the elements making up the kit.
C
33
1
2
3
4
5
6
7
24
The adapter kit includes (Fig. 24):
N°1 Gasket (1)
N°1 Adapter Ø 80/125 (2)
The Kit Ø 80/125 includes (Fig. 24):
N°1 Wall sealing plate (3)
N°1 Aluminium tile (4)
N°1 Fixed half-shell (5)
N°1 Mobile half-shell (6)
N°1 Concentric intake/exhaust pipe Ø 80/125 (7)
The remaining kit components must not be used