Technical Documentation
Technical Documentation
Technical Data.
VICTRIX 26 2 I technical data.
- Flue temperature values refer to an air inlet temperature of 15°C
and delivery temperature of 50°C.
- The data relevant to domestic hot water performance refer to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
the values are measured directly at the boiler outlet considering that
to obtain the data declared mixing with cold water is necessary.
- The maximum sound level emitted during boiler operation is <
55dBA. The sound level value is referred to semianechoic chamber
tests with boiler operating at max. heat output, with extension of
fume exhaust system according to product standards.
- * Specific capacity “D”: domestic hot water flow rate corresponding
to an average increase of 30K, which the boiler can supply in two
successive withdrawals.
Domestic hot water nominal heat input
kW (kcal/h)
26.7 (22933)
Central heating nominal heat input
kW (kcal/h)
24.1 (20747)
Minimum heat input
kW (kcal/h)
3.2 (2719)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
26.0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23.6 (20296)
Minimum heat output (useful)
kW (kcal/h)
3.0 (2580)
Efficiency 80/60 Nom./Min.
%
97.8 / 94.9
Efficiency 50/30 Nom./Min.
%
106.7 / 103.0
Efficiency 40/30 Nom./Min.
%
108.1 / 107.1
Heat loss at casing with burner On/Off (80-60°C)
%
0.41 / 0.50
Heat loss at flue with burner On/Off (80-60°C)
%
0.02 / 2.00
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature Pos 1
°C
25 - 85
Adjustable central heating temperature Pos 2
°C
25 - 50
System expansion vessel total volume
l
5.7
Expansion vessel factory-set pressure
bar
1
Water content in generator
l
3.4
Total head available with 1000/h flow rate
kPa (m H
2
O)
18.63 (1.90)
Hot water production useful heat output
kW (kcal/h)
26.0 (22360)
Domestic hot water adjustable temperature
°C
30 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
8.75
Min. pressure (dynamic) domestic hot water circuit
bar
0.3
Domestic hot water circuit max. working pressure
bar
10
*Specific capacity “D” according to EN 625
l/min
11.8
Drawing capacity in continuous duty (∆T 30°C)
l/min
12.9
Weight of full boiler
kg
42.4
Weight of empty boiler
kg
39.0
Electric connection
V/Hz
230/50
Power input
A
0.61
Installed electric power
W
135
Pump consumption
W
83.5
Fan consumption
W
10
Equipment electrical system protection
-
IPX4D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
39.0
Weighted CO
mg/kWh
17.2
Type of appliance
C13 / C23 / C33 / C43 / C53 / C83 / B23p
/ B33p
Category
II2H3B/P