Vertical kit with aluminium tile Ø 80/125.
Kit
assembly (Fig. 1-20): install the concentric flange
(2) on the central hole of the boiler inserting the
gasket (1) and tighten using the screws in the
kit. Fit the male end (smooth) of the adapter (3)
into the female end of the concentric flange (2).
Imitation aluminium tile installation. Replace the
tile with the aluminium sheet (5), shaping it to
ensure that rainwater runs off. Position the fixed
half-shell (7) and insert the intake-exhaust pipe
(6). Fit the Ø 80/125 concentric terminal pipe
with the male end (6) (smooth) to the female
end of the adapter (3) (with lip gasket) up to the
stop; making sure that the wall sealing plate has
been fitted, this will ensure sealing and joining
of the elements making up the kit.
• Coupling extension pipes and concentric
elbows. To install push-fitting extensions
with other elements of the flue extraction
elements assembly, proceed as follows: engage
the concentric pipe or elbow with the male
side (smooth) on the female section (with lip
seal) up to the stop on the previously installed
element. This will ensure sealing and joining
of the elements correctly.
Important:
if the exhaust terminal and/or exten-
sion concentric pipe needs shortening, consider
that the internal pipe must always protrude by
5 mm with respect to the external pipe.
This specific terminal enables flue exhaust and
air intake, necessary for combustion, in a vertical
direction.
N.B.:
The Ø 80/125 vertical kit with aluminium
tile enables installation on terraces and roofs
with a maximum slope of 45% (25°) and the
height between the terminal cap and half-shell
(374 mm) must always be respected.
The vertical kit with this configuration can be
extended up to a
maximum of 12,200 mm
vertical
rectilinear, with the terminal included (Fig. 1-21).
This configuration corresponds to a resistance
factor of 100. In this case the special extensions
must be requested.
The terminal Ø 60/100 can also be used for
vertical exhaust, in conjunction with concentric
flange code 3.011141 (sold separately). The
height between the terminal cap and half-shell
(374 mm) must always be respected.
The vertical kit with this configuration can be
extended up to a
maximum of 4,700 mm
vertical
rectilinear, with the terminal included (Fig. 1-21).
Separator kit Ø 80/80.
The Ø 80/80 separator kit,
allows separation of the exhaust flues and air intake
pipes according to the diagram shown in the figure
.
Combustion products are expelled from pipe (S).
Air is taken in through pipe (A) for combustion.
The intake pipe (A) can be installed either on the
right or left hand side of the central exhaust pipe
(S). Both ducts can be routed in any direction.
• Kit assembly (Fig. 1-22): install flange (4) on the
central hole of the boiler, fitting gasket (1) and
tighten with the flat-tipped hex screws included
in the kit. Remove the flat flange present in the
lateral hole with respect to the central one (ac-
cording to needs) and replace it with the flange
(3), positioning the gasket (2) already present in
the boiler and tighten using the supplied self-
threading screws. Fit the male end (smooth) to
the bends (5) in the female end of the flanges
(3 and 4). Fit the intake terminal (6) with the
male section (smooth) in the female section of
the bend (5) up to the stop, ensuring that the
internal and external wall sealing plates are
fitted. Fit the exhaust pipe (9) with the male end
(smooth) to the female end of the bend (5) up
to the stop; making sure that the internal wall
sealing plate has been fitted, this will ensure
sealing and joining of the elements making up
the kit.
The kit includes:
N°1 - Gasket (1)
N°1 - Female concentric flange
(2)
N°1 - Adapter Ø 60/100
for Ø 80/125 (3)
N°1 - Wall sealing plate (4)
N°1 - Aluminium tile (5)
N°1 - Concentric intake-
exhaust terminal
Ø 80/125 (6)
N°1 - Fixed half-shell (7)
N°1 - Mobile half-shell (8)
The kit includes:
N°1 - Gasket (1)
N°1 - Concentric bend Ø 60/100 (2)
N°1 - Adapter Ø 60/100 for Ø 80/125 (3)
N°1 - Int./exhaust concentric terminal
Ø 80/125 (4)
N°1 - Internal wall sealing plate (5)
N°1 - External wall sealing plate (6)
Содержание Maior Eolo 24 4E
Страница 1: ...MAIOR EOLO 24 28 32 4E Instruction and warning booklet IE 1 038771ENG ...
Страница 2: ......
Страница 30: ...30 3 5 4 4 5 6 6 d d c INSTALLER USER MAINTENANCE TECHNICIAN ...
Страница 35: ......