44
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
A
N
3.19 TECHNICAL DATA.
BOILER TECHNICAL DATA
Domestic hot water nominal heat input
kW (kcal/h)
26.9 (23147)
Central heating nominal heat input
kW (kcal/h)
24.3 (20904)
Minimum heat input
kW (kcal/h)
3.2 (2768)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
26.0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23.6 (20253)
Minimum heat output (useful)
kW (kcal/h)
3.0 (2580)
*Effective thermal efficiency 80/60 Nom./Min.
%
96.9 / 93.2
*Effective thermal efficiency 50/30 Nom./Min.
%
105.3 / 106.8
*Effective thermal efficiency 40/30 Nom./Min.
%
107.5 / 108.8
Casing losses with burner On/Off (80-60°C)
%
0.70 / 0.90
Heat loss at flue with burner On/Off (80-60°C)
%
0.05 / 2.50
Central heating circuit max. operating pressure
bar
3
Maximum heating temperature
°C
90
Max. adjustable central heating temperature
°C
25 - 85
Min. adjustable central heating temperature
°C
25 - 50
System expansion vessel total volume
l
10.8
Heating expansion vessel pre-charge
bar
1.0
Total volume domestic hot water expansion vessel
l
4.3
Domestic hot water expansion vessel pre-charge
bar
2.5
Appliance water content
l
7.6
High temperature zone total head available with 1000 l/h flow rate
kPa (m H
2
O)
28.8 (2.94)
Low temperature zone total head available with 1000 l/h flow rate
kPa (m H
2
O)
35.0 (3.57)
Hot water production useful heat output
kW (kcal/h)
26.0 (22360)
Domestic hot water adjustable temperature
°C
20 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
29.3
Domestic hot water circuit min. pressure (dynamic)
bar
0.3
Domestic hot water circuit max. operating pressure
bar
8.0
**Specific flow rate “D” according to EN 625
l/min
19.0
Flow rate capacity in continuous duty (∆T 30°C)
l/min
13.1
Domestic hot water performance classification according to N 13203-1
Weight of full boiler
kg
404.4
Weight of empty boiler
kg
193.8
Electrical connection
V/Hz
230 / 50
Nominal power absorption
A
1.2
Installed electric power
W
165
Boiler circulator pump absorbed power
W
30.6
Zone pump absorbed power
W
58.5
Fan power absorbed power
W
23.0
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
52
Weighted CO
mg/kWh
15
Type of appliance
C13 / C13x / C23 / C33 / C33x / C43 / C43x / C53 / C63
/ C83 / C93 / C93x / B23p / B23 / B53p
Category
II2H3B/P
SOLAR CIRCUIT TECHNICAL DATA
Maximum continuous operating temperature
°C
130
Maximum peak temperature
°C
150
Safety valve pressure
bar
6
Total volume hot water expansion vessel
l
10.8
Expansion vessel factory-set pressure
bar
2.5
Content of glycol in the solar circuit
l
2.0
Pump absorbed power
W
33.9
Head available with 800 l/h flow rate
kPa (m H
2
O)
46.7 (4.76)
Flow rate regulator control range
l/min
1 - 6
- Flue temperature values refer to an air inlet
temperature of 15°C and flow temperature of
50°C.
- The data relevant to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet consider-
ing that to obtain the data declared mixing with
cold water is necessary.
- * Yields refer to the lower heating value.
- ** Specific flow rate ''D'': domestic hot water
flow rate corresponding to an average tem-
perature increase of 30K, which the boiler can
supply in two subsequent withdrawals.
Содержание HERCULES SOLAR 26 2 ErP
Страница 1: ...HERCULES SOLAR 26 2 ErP Instruction and recommendation booklet IE 1 037974ENG ...
Страница 2: ......
Страница 40: ...40 3 7 7 8 9 INSTALLER USER MAINTENANCE TECHNICIAN ...
Страница 42: ...42 3 9 Part E 17 19 18 18 18 18 INSTALLER USER MAINTENANCE TECHNICIAN Part E ...
Страница 51: ......